5 OPERATION
0463 815 001
- 31 -
© ESAB AB 2021
5.4.2
Firepower FP-200
1. Spool gun indicator
When the correct ESAB Spool-Gun* is connected, the LED will illuminate. (*Optional Accessory)
2. Thermal overload indicator (fault indicator)
This welding power source is protected by a self resetting thermostat. The LED indicator will
illuminate if the duty cycle of the power source has been exceeded. Should the thermal
overload indicator illuminate the output of the power source will be disabled. Once the power
source cools down, the LED will turn OFF and the over temperature condition will
automatically reset. Note that the mains power switch should remain in ON position such that
the fan continues to operate thus allowing the unit to cool sufficiently. Do not switch the unit
OFF during an overload condition.