ESAB FABRICATOR 181i
TROUBLESHOOTING 6-8 Manual 0-5449
6.11 DC Bus Voltage Measurement
Apply voltage to the Power Source.
WARNING
There are extremely dangerous voltage and power levels present inside these Power Sources. Do not
attempt to diagnose or repair unless you have had training in power electronics measurement and
troubleshooting techniques.
Once power is applied to the Power Source, there are extremely hazardous voltage and power levels
present.
Do not touch any live parts.
4
3
1
2
5
6
7
8
10
9
12
11
14
13
16
15
17
18
19
20
21
22
A-09988
DC Bus Testing
Multimeter Lead Placement
Voltage with Supply Voltage OFF
Upper capacitor bank
Positive meter lead to testpoint 1
Negative meter lead to testpoint 2
161 VDC +/-10%
Lower capacitor bank
Positive meter lead to testpoint 3
Negative meter lead to testpoint 4
161 VDC +/-10%
Overall capacitor bank
Positive meter lead to testpoint 1
Negative meter lead to testpoint 4
322 VDC +/-10%
Table 6-9 DC BUS, Multimeter set to measure DC volts
Note: These DC voltages are at nominal mains supply voltage of 230VAC.
Содержание Fabricator 181i
Страница 18: ...ESAB FABRICATOR 181i SAFETY AND INSTALLATION 3 8 Manual 0 5449 This Page Intentionally Blank...
Страница 40: ...ESAB FABRICATOR 181i THEORY OF OPERATION 5 2 Manual 0 5449 This Page Intentionally Blank...
Страница 64: ...ESAB FABRICATOR 181i DISASSEMBLY PROCEDURES 7 4 Manual 0 5449 A 09965_AB...
Страница 71: ...ESAB FABRICATOR 181i Manual 0 5449 8 3 ASSEMBLY PROCEDURES 8 7 A 10011 9 A 10114...
Страница 73: ...ESAB FABRICATOR 181i Manual 0 5449 8 5 ASSEMBLY PROCEDURES A 09965_AB...
Страница 76: ...ESAB FABRICATOR 181i ASSEMBLY PROCEDURES 8 8 Manual 0 5449 This Page Intentionally Blank...
Страница 79: ...ESAB FABRICATOR 181i Manual 0 5449 9 3 KEY SPARE PARTS Art A 10363 31 9 03 Power Source Art A 11243_AC...
Страница 82: ...REVISION HISTORY Date Rev Description 09 18 2015 AA Manual release...
Страница 83: ......