background image

Filter jam

Low battery

Over heat

Air outlet jam

Current overload

Turn OFF the system

Change air flow speed

Turn ON the system

Install the battery

100ms per grid

10

9

8

7

6

5

4

3

2

1

0

Symbols:

=Read instructions before use

      

2797

CE mark followed by number of notified body who carried 

out module D surveillance.

Warranty:

The EPR-X1 Blower unit is guaranteed for a period of 12 months from date of purchase 
against mechanical or electrical defects.
The EPR-X1 battery is guaranteed for a period of 6 months from the date of purchase.
The company undertakes to exchange or repair without charge, if any part found to be 
defective within this period alternatively and at it’s discretion. The Company may replace.
This guarantee is subject to:
The EPR-X1 unit has been used solely for the purpose for which it is intended.

The EPR-X1 unit has not been subject to misuse, accident, modification or repair.

In the event of a claim, contact the retailer from which the EPR-X1 unit was purchased.
The guarantee does not cover normal wear and tear.

Содержание EPR-X1

Страница 1: ...tor User Instructions Please read these instructions carefully before using the equipment Incorrect use can result in danger to life and health Manual Number 0700500912 Revision Date 03 08 2022 Revisi...

Страница 2: ...Can injure eyes and burn skin The arc like the sun emits ultraviolet UV and other radiation and can injure skin and eyes Hot metal can cause burns Training in the proper use of the processes and equi...

Страница 3: ...all combustible materials well away from the work area or cover the materials with a protective non flammable covering Combustible materials include wood cloth sawdust liquid and gas fuels solvents p...

Страница 4: ...ioning properly please do not Alter or modify in any way Touch any of the moving parts Allow water or other liquids to enter the impeller chamber the filter or battery com partment Make sure blower mo...

Страница 5: ...rs 2 Only listed particulate filter and pre filter can be used together with this sys tem Filters from other manufacturers shouldn t be used under any circumstances and voids both the certification an...

Страница 6: ...belt and the shoulder harness 2 EPR X1 blower assembly 3 Rechargeable lithium ion battery 4 Battery charger 5 The air flow tester 6 Main HEPA filter assembly includes pre filter and spark arrestor no...

Страница 7: ...Clean the spark arrestor if necessary 6 Install a new filter by reversing the ac tions in steps 3 and 4 If the filter is wet or heavily loaded with particles or damaged it should be replaced Never at...

Страница 8: ...y is fully charged it will maintain it at a 100 floating charge The charge time is 3 to 4 hours The battery will discharge itself after long storage periods Always charge the bat tery if the device wa...

Страница 9: ...n 2 Unlock the hook and loop fastener and pass through the blower assem bly s belt loops 3 Pass the fastening belt through the gap on belt 4 Attach the hook and loop fastener onto the belt 5 Attach th...

Страница 10: ...be to the Respira tory System and twist it clockwise to lock its position 1 Check that the respiratory tube is securely connected If the tube is broken replace it WARNING All components must be instal...

Страница 11: ...he top of the tube 3 Press the ON button and maintain the tube in a vertical position at eye height 4 The air flow is sufficient if the marble reaches the minimum flow level O WARNING 1 The airflow mu...

Страница 12: ...does not work please repair or change Respiratory System 6 3 Fitting 1 Adjust the tightness of the face seal and put on the head top 2 Adjust the headgear to suitable tight ness push and turn left to...

Страница 13: ...tton and hold for 3 seconds the air flow will be at level 1 170L min Press the ON button once again the air flow will be at level 2 190L min Press the ON button once again the air flow will be at leve...

Страница 14: ...PAPR P3 filter 4 700500904 EPR X1 PAPR battery 5 700500905 EPR X1 PAPR filter cover 6 700500906 EPR X1 PAPR spark arrestor 7 700500907 EPR X1 PAPR breathing tube 8 700500908 EPR X1 PAPR FR fabric tube...

Страница 15: ...al surfaces Do not use water or other liquids Always replace the pre filter when the main filter is replaced 9 2 Storage The Respiratory System must be stored in a dry clean area in the temperature ra...

Страница 16: ...nit OFF and allow it to cool No air flow no alarm 1 No power 2 Battery contact dam aged Charge the battery Check battery contact Battery run time is too short 1 Battery is not fully charged 2 Filter b...

Страница 17: ...acity Filter status 12 MARKING EXPLANATION Powered filtering device EN 12941 1998 Respiratory protective devices Powered filtering devices incorporating a helmet or hood Requirements testing marking T...

Страница 18: ...echanical or electrical defects The EPR X1 battery is guaranteed for a period of 6 months from the date of purchase The company undertakes to exchange or repair without charge if any part found to be...

Страница 19: ...This page intentionally blank...

Страница 20: ...ESAB Group Inc 2800 Airport Road Denton TX 76207 USA...