3 TECHNICAL DATA
0463 605 001
- 10 -
© ESAB AB 2018
Dimensions
l × w × h
686 × 292 × 495 mm (27.0 × 11.5 × 19.5 in.)
Weight
31.75 kg (70.0 lb)
Enclosure class
IP23
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or
cut at a certain load without overloading. The duty cycle is valid for 40 °C (104 °F).
Enclosure class
The
IP
code indicates the enclosure class, i.e. the degree of protection against penetration
by solid objects or water.
Equipment marked
IP 23S
is intended for indoor and outdoor use; however, should not be
operated in precipitation.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.