9. Connect the opposite end of individual wires to
a customer supplied plug or main disconnect.
10. Connect the input power cable (or close the main
disconnect switch) to supply power.
3.06 Gas Connections
Connecting Gas Supply to Unit
The connection is the same for compressed air or high
pressure cylinders. Refer to the following subsections
if an optional air line filter is to be installed.
1. Connect the air line to the inlet port. The illustra-
tion shows typical fittings as an example.
NOTE!
For a secure seal, apply thread seal-
ant to the fitting threads, according
to the manufacturer's instructions.
Do Not use Teflon tape as a thread
sealer, as small particles of the tape
may break off and block the small air
passages in the torch.
Art # A-08320
Inlet Port
Filter Assembly
Hose Clamp
Gas Supply
Hose
1/4 NPT or ISO-R
to 1/4” (6mm) Fitting
Air Connection to Inlet Port
Installing Optional Single - Stage Air Filter
An optional filter kit is recommended for improved filter
-
ing with compressed air, to keep moisture and debris
out of the torch.
1. Attach the Single - Stage Filter Hose to the Inlet
Port.
2. Attach the Filter Assembly to the filter hose.
3. Connect the air line to the Filter. The illustration
shows typical fittings as an example.
NOTE!
For a secure seal, apply thread seal-
ant to the fitting threads, according
to the manufacturer's instructions.
Do Not use Teflon tape as a thread
sealer, as small particles of the tape
may break off and block the small air
passages in the torch. Connect as
follows:
Art # A-08319
Hose Clamp
1/4 NPT to 1/4"
(6mm) Fitting
Inlet Port
Gas Supply
Hose
Filter Assembly
Optional Single - Stage Filter Installation
Using High Pressure Air Cylinders
When using high pressure air cylinders as the air supply:
1. Refer to the manufacturer’s specifications for
installation and maintenance procedures for high
pressure regulators.
2. Examine the cylinder valves to be sure they are
clean and free of oil, grease or any foreign mate-
rial. Briefly open each cylinder valve to blow out
any dust which may be present.
3. The cylinder must be equipped with an adjust-
able high - pressure regulator capable of outlet
pressures up to 100 psi (6.9 bar) maximum and
flows of at least 300 scfh (141.5 lpm).
4. Connect supply hose to the cylinder.
Содержание CUTMASTER A40
Страница 5: ......
Страница 8: ...This Page Intentionally Blank...
Страница 18: ...CUTMASTER A60 INTRODUCTION 0 5428 2T 4 This Page Intentionally Blank...
Страница 24: ...CUTMASTER A60 INSTALLATION 0 5428 3 6 This Page Intentionally Blank...
Страница 32: ...CUTMASTER A60 OPERATION 0 5428 4 4 This Page Intentionally Blank...
Страница 58: ...CUTMASTER A60 OPERATION 0 5428 4T 26 This page intentionally blank...
Страница 59: ...CUTMASTER A60 0 5428 OPERATION 4T 27 This page intentionally blank...
Страница 80: ...CUTMASTER A60 OPERATION 0 5428 4T 48 This Page Intentionally Blank...
Страница 98: ...CUTMASTER A60 PARTS LIST 0 5428 6 8 This Page Intentionally Blank...
Страница 110: ...CUTMASTER A60 APPENDIX 0 5428 A 12 REVISION HISTORY Date Rev Description 09 25 2015 AA Manual release...
Страница 111: ...This page intentionally blank...