ESAB Caddyt Tig 150i Скачать руководство пользователя страница 4

-- 4 --

bt26d2e

WARNING

READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE INSTALLING OR OPERATING.

ARC WELDING AND CUTTING CAN BE INJURIOUS TO YOURSELF AND OTHERS. TAKE PRECAU-

TIONS WHEN WELDING. ASK FOR YOUR EMPLOYER’S SAFETY PRACTICES WHICH SHOULD BE

BASED ON MANUFACTURERS’ HAZARD DATA.

ELECTRIC SHOCK -- Can kill

S

Install and earth the welding unit in accordance with applicable standards.

S

Do not touch live electrical parts or electrodes with bare skin, wet gloves or wet clothing.

S

Insulate yourself from earth and the workpiece.

S

Ensure your working stance is safe.

FUMES AND GASES -- Can be dangerous to health

S

Keep your head out of the fumes.

S

Use ventilation, extraction at the arc, or both, to take fumes and gases away from your breathing zone

and the general area.

ARC RAYS -- Can injure eyes and burn skin.

S

Protect your eyes and body. Use the correct welding screen and filter lens and wear protective

clothing.

S

Protect bystanders with suitable screens or curtains.

FIRE HAZARD

S

Sparks (spatter) can cause fire. Make sure therefore that there are no inflammable materials nearby.

NOISE -- Excessive noise can damage hearing

S

Protect your ears. Use earmuffs or other hearing protection.

S

Warn bystanders of the risk.

MALFUNCTION -- Call for expert assistance in the event of malfunction.

PROTECT YOURSELF AND OTHERS!

ESAB can provide you with all necessary welding protection and accessories.

WARNING!

Read and understand the instruction manual before installing

or operating.

Do not use the power source for thawing frozen pipes.

WARNING!

This product is solely intended for arc welding.

Do not dispose of electrical equipment together with normal waste!

In observance of European Directive 2002/96/EC on Waste Electrical and Electronic

Equipment and its implementation in accordance with national law, electrical equipment

that has reached the end of its life must be collected separately and returned to an

environmentally compatible recycling facility. As the owner of the equipment, you should

get information on approved collection systems from our local representative.
By applying this European Directive you will improve the environment and human health!

GB

Содержание Caddyt Tig 150i

Страница 1: ...GB Valid for serial no 620 xxx xxxx 0459 262 201 060523 Tig 150i Tig 200i Origot TA33 Instruction manual...

Страница 2: ...6 5 1 Placing 6 5 2 Rating plate 6 5 3 Mains power supply 7 6 OPERATION 8 6 1 Connections and control devices 8 6 2 Control panel TA33 9 6 3 Overheating protection 9 7 WELDING 10 7 1 TIG welding 10 7...

Страница 3: ...work must be carried out by trained personnel well acquainted with the operation of the welding equipment Incorrect oper ation of the equipment may lead to hazardous situations which can result in inj...

Страница 4: ...ARD S Sparks spatter can cause fire Make sure therefore that there are no inflammable materials nearby NOISE Excessive noise can damage hearing S Protect your ears Use earmuffs or other hearing protec...

Страница 5: ...rmissible load at MMA 25 duty cycle 35 duty cycle 60 duty cycle 100 duty cycle 150 A 26 V 140 A 25 5 V 110 A 24 5 V 90 A 23 5 V 150 A 26 V 140 A 25 5 V 110 A 24 5 V 90 A 23 5 V Power factor at maximum...

Страница 6: ...The installation must be executed by a professional WARNING This product is intended for industrial use In a domestic environment this product may cause radio interference It is the user s responsibi...

Страница 7: ...10 1 phase 230 V 10 1 fas Mains frequency 50 60 Hz 50 60 Hz Fuse delayed action 85A 35 duty cycle MMA 120A 20 duty cycle MMA 150A 25 duty cycle MMA 10 A 16 A 20 A 10 A 16 A 20 A Mains cable area 3 x 2...

Страница 8: ...ed to the correct supply voltage and that it is protected by the correct fuse rating 1 Mains switch 6 TIG torch connection 2 Connection gas bottle connector 7 Connection for return cable MMA 3 Mains c...

Страница 9: ...E G TIG TIG HF 2 stroke MMA LiftArct 4 stroke G Slope down F Gas post flow 6 3 Overheating protection The welding power source has a thermal overload trip which operates if the temperature becomes to...

Страница 10: ...s post flow Functions when using 4 stroke control of the welding torch In the 4 stroke control mode pressing the trigger switch starts gas pre flow if used 1 At the end of the gas pre flow time the cu...

Страница 11: ...workpiece the arc strikes and the current rises automatically to the set value 7 1 5 Gas post flow This controls the time during which shielding gas flows after the arc is extinguished 7 1 6 Slope do...

Страница 12: ...ong it will crackle and spit before finally going out com pletely If you are working on a welding bench check before attempting to strike the arc that residual waste metal pieces of electrode or other...

Страница 13: ...turn cables are correctly connected S Check that the correct current value is set S Check that the correct electrodes are being used 9 1 Fault codes The Tig 150i Tig 200i comes with built in fault mon...

Страница 14: ...Diagram 14 Tig150i...

Страница 15: ...15 Tig150i...

Страница 16: ...Diagram 16 Tig200i...

Страница 17: ...17 Tig200i...

Страница 18: ...200 881 Welding power source OrigotTig 150i TA33 for 230 V mains voltage 0459 200 887 Welding power source OrigotTig 150I TA33 for 230 V mains voltage Australian version 0459 200 883 Welding power sou...

Страница 19: ...19 Access MMA welding and return cable kit crocodile type holder 0349 501 078 MMA welding and return cable kit screwe type holder 0349 501 079 Shoulderstrap 0459 368 880 Trolley small gas bottle 0459...

Страница 20: ...22 ESAB international AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires Tel...

Отзывы: