3 TECHNICAL DATA
0463 431 001
- 8 -
© ESAB AB 2016
3
TECHNICAL DATA
Mig 4004i Pulse
Mains voltage
380-460V, ±10%, 3~ 50/60 Hz
Mains supply S
scmin
5.8 MVA
Primary current I
max
19 A
No-load power
99 W
Setting range (DC)
MIG/MAG
16 A / 14.8 V - 400 A / 34 V
MMA
16 A / 20.6 V - 400 A / 36 V
TIG
4 A / 10.2 V - 400 A / 26 V
Permissible load at MIG/MAG
60 % duty cycle
400 A / 34.0 V
100% duty cycle
300 A / 29.0 V
Permissible load at MMA
60 % duty cycle
400 A / 36.0 V
100% duty cycle
300 A / 32.0 V
Permissible load at TIG
60 % duty cycle
400 A / 26.0 V
100% duty cycle
300 A / 22.0 V
Power factor
at maximum current
0.95
Efficiency
at maximum current
89.5 %
Open circuit voltage
55 V
Operating temperature
-10 to 40°C (14 to 104°F)
Transport temperature
-20 to 55°C (-4 to 131°F)
Constant sound pressure when idling
<70 dB (A)
Dimensions l×w×h
445 × 250 × 380 mm (24.0 × 9.8 × 15”)
Weight
45 kg (96 lbs)
Insulation class
H
Enclosure class
IP 23
Application classification
Mains supply, S
sc min
Minimum short circuit power on the network in accordance with IEC 61000-3-12.
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or
cut at a certain load without overloading. The duty cycle is valid for 40°C / 104°F, or below.
Enclosure class
The
IP
code indicates the enclosure class, i. e. the degree of protection against penetration
by solid objects or water.
Equipment marked
IP23
is intended for indoor and outdoor use.