ESAB Aristo RoboFeed 3004w Скачать руководство пользователя страница 3

-- 3 --

bm40d1ea

1

DIRECTIVE

DECLARATION OF CONFORMITY

ESAB AB, Welding Equipment, SE--695 81 Laxå, Sweden, declares that Wire feed unit RoboFeed

3004w from serial number 620 onwards, conforms to standard IEC/EN 60974--5, in accordance with

the requirements of directive (73/23/EEC) and appendix (93/68/EEC) and standard IEC/EN 60974--10

in accordance with the requirements of directive (89/336/EEC) and appendix (93/68/EEC).

--------------------------------------------------------------------------------------------------------------------------------------

Kent Eimbrodt

Global Director Equipment and Automation

ESAB AB

695 81 LAXÅ

SWEDEN

Tel: + 46 584 81000

Fax: + 46 584 411924

Laxå 2006--05--22

2

SAFETY

Users of ESAB welding equipment have the ultimate responsibility for ensuring that anyone who

works on or near the equipment observes all the relevant safety precautions. Safety precautions

must meet the requirements that apply to this type of welding equipment. The following recommen-

dations should be observed in addition to the standard regulations that apply to the workplace.

All work must be carried out by trained personnel well--acquainted with the operation of the welding

equipment. Incorrect operation of the equipment may lead to hazardous situations which can result

in injury to the operator and damage to the equipment.
1.

Anyone who uses the welding equipment must be familiar with:

S

its operation

S

location of emergency stops

S

its function

S

relevant safety precautions

S

welding

2.

The operator must ensure that:

S

no unauthorized person is stationed within the working area of the equipment when it is

started up.

S

no--one is unprotected when the arc is struck

3.

The workplace must:

S

be suitable for the purpose

S

be free from drafts

4.

Personal safety equipment

S

Always wear recommended personal safety equipment, such as safety glasses, flame--proof

clothing, safety gloves.

S

Do not wear loose--fitting items, such as scarves, bracelets, rings, etc., which could become

trapped or cause burns.

5.

General precautions

S

Make sure the return cable is connected securely.

S

Work on high voltage equipment

may only be carried out by a qualified electrician.

S

Appropriate fire extinquishing equipment must be clearly marked and close at hand.

S

Lubrication and maintenance must

not

be carried out on the equipment during operation.

GB

Содержание Aristo RoboFeed 3004w

Страница 1: ...GB Valid for serial no 620 xxx xxxx 0461 030 101 GB 060523 RoboFeed 3004w Aristot Instruction manual...

Страница 2: ...nating resistor 6 5 2 Example of a robotic welding system 6 6 OPERATION 7 6 1 Connections and control devices 7 6 2 Gas flow guard if installed 8 6 3 Wire feed pressure 9 6 4 Replacing and inserting w...

Страница 3: ...d with the operation of the welding equipment Incorrect operation of the equipment may lead to hazardous situations which can result in injury to the operator and damage to the equipment 1 Anyone who...

Страница 4: ...le screens or curtains FIRE HAZARD S Sparks spatter can cause fire Make sure therefore that there are no inflammable materials nearby NOISE Excessive noise can damage hearing S Protect your ears Use e...

Страница 5: ...nsion Fe Ss Al Cored wire 0 6 1 6 mm 0 6 1 2 mm 1 0 1 6 mm 0 8 1 6 mm Weight 7 3 kg Dimensions l x b x h 362 x 246 x 235 mm Shielding gas max pressure Gases for MIG MAG welding 5 bar Coolant max press...

Страница 6: ...y power sources intended for this environment may be used These power sources are marked with the symbol 5 1 Terminating resistor The ends of the CAN bus must be fitted with terminating resistors to a...

Страница 7: ...t connection for spatter removal air 3 Switch for reversed wire feed 11 Connection for coolant from power source cooling unit BLUE 4 Switch for cold wire feed 12 Connection for coolant to power source...

Страница 8: ...moisture before commencing welding Gas purging is carried out with the voltage and wire feed switched off Reversed wire feed 3 Used to reverse the wire for example when replacing the wire bobbin Inch...

Страница 9: ...essure rollers slide up S Straighten out the new wire 10 20 cm File away burrs and sharp edges from the end of the wire before inserting it into the wire feed unit S Make sure that the wire goes prope...

Страница 10: ...if pre tensioning is set too hard this can result in abnormal wear on the pressure roller feed roller and wire guide Welding gun S Cleaning and replacement of the welding gun s wear parts should take...

Страница 11: ...11 p...

Страница 12: ...Edition 060523 Diagram 12 bm40e...

Страница 13: ...Edition 060523 13 bm40e...

Страница 14: ...14 p...

Страница 15: ...Wire feed unit Spare parts list AristotRoboFeed 3004w AristotRoboFeed 3004w AristotRoboFeed 3004w 23 pole 12 pole The spare parts list is available on the Internet at www esab com Under Products and...

Страница 16: ...3 Feed pressure rollers Cored 1 6 mm V Knurled 1 6 R2 2 0 R2 0458 824 001 Feed pressure rollers Al 0 8 0 9 1 0 mm U 0 8 A2 1 0 A2 0458 824 002 Feed pressure rollers Al 1 0 1 2 mm U 1 0 A2 1 2 A2 0458...

Страница 17: ...RoboFeed 3004w R0461 030 E060523 PNO TAG 17 bm29whj1...

Страница 18: ...bm40a Connection plate compl 12 pol 0461 057 880 Quick connector MarathonPact F102 440 880 Adapter with needle bearing 0455 053 881 Adapterplate for mounting on the robot arm 0461 038 880 Cover 0461...

Страница 19: ...19 p...

Страница 20: ...22 ESAB international AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires Tel...

Отзывы: