ESAB Aristo Mig 4001i Скачать руководство пользователя страница 5

1 SAFETY

0460 740 001

- 5 -

© ESAB AB 2017

4.

Personal safety equipment:

○ Always wear recommended personal safety equipment, such as safety glasses,

flame-proof clothing, safety gloves

○ Do not wear loose-fitting items, such as scarves, bracelets, rings, etc., which

could become trapped or cause burns

5.

General precautions:

○ Make sure the return cable is connected securely
○ Work on high voltage equipment

may only be carried out by a qualified

electrician

○ Appropriate fire extinguishing equipment must be clearly marked and close at

hand

○ Lubrication and maintenance must

not

be carried out on the equipment during

operation

WARNING!

Arc welding and cutting can be injurious to yourself and others. Take precautions
when welding and cutting.

ELECTRIC SHOCK - Can kill

• Install and ground the unit in accordance with instruction manual.
• Do not touch live electrical parts or electrodes with bare skin, wet gloves or

wet clothing.

• Insulate yourself from work and ground.
• Ensure your working position is safe

ELECTRIC AND MAGNETIC FIELDS - Can be dangerous to health

• Welders having pacemakers should consult their physician before welding.

EMF may interfere with some pacemakers.

• Exposure to EMF may have other health effects which are unknown.
• Welders should use the following procedures to minimize exposure to

EMF:

○ Route the electrode and work cables together on the same side of

your body. Secure them with tape when possible. Do not place your
body between the torch and work cables. Never coil the torch or
work cable around your body. Keep welding power source and
cables as far away from your body as possible.

○ Connect the work cable to the workpiece as close as possible to the

area being welded.

FUMES AND GASES - Can be dangerous to health

• Keep your head out of the fumes.
• Use ventilation, extraction at the arc, or both, to take fumes and gases

away from your breathing zone and the general area.

ARC RAYS - Can injure eyes and burn skin

• Protect your eyes and body. Use the correct welding screen and filter lens

and wear protective clothing.

• Protect bystanders with suitable screens or curtains.

NOISE - Excessive noise can damage hearing

Protect your ears. Use earmuffs or other hearing protection.

Содержание Aristo Mig 4001i

Страница 1: ...Origo Aristo Instruction manual 0460 740 001 GB 20170604 Valid for 833 xxx xxxx 852 xxx xxxx Mig 4001i...

Страница 2: ......

Страница 3: ...ION 12 5 1 Connections and control devices 12 5 2 Connection of welding and return cable 12 5 3 Turning on the power source 12 5 4 Fan control 13 5 5 Overheating protection 13 5 6 MIG MAG and FCAW S w...

Страница 4: ...y precautions must meet the requirements that apply to this type of equipment The following recommendations should be observed in addition to the standard regulations that apply to the workplace All w...

Страница 5: ...ELECTRIC AND MAGNETIC FIELDS Can be dangerous to health Welders having pacemakers should consult their physician before welding EMF may interfere with some pacemakers Exposure to EMF may have other he...

Страница 6: ...uipment is not intended for use in residential locations where the electrical power is provided by the public low voltage supply system There may be potential difficulties in ensuring electromagnetic...

Страница 7: ...without cooling unit The cooling unit can be retro fitted The power source is supplied with 5 m return cable with contact clamp 5 m mains cable with 32 Amp connector instruction manual for the welding...

Страница 8: ...34 V 60 duty cycle 320 A 30 V 100 duty cycle 250 A 26 5 V Permissible load at TIG 30 duty cycle 400 A 26 V 60 duty cycle 320 A 22 8 V 100 duty cycle 250 A 20 V Permissible load at MMA 30 duty cycle 40...

Страница 9: ...the control panel Mains supply Ssc min Minimum short circuit power on the network in accordance with IEC 61000 3 12 Duty cycle The duty cycle refers to the time as a percentage of a ten minute period...

Страница 10: ...This equipment complies with IEC 61000 3 12 provided that the short circuit power is greater than or equal to Sscmin at the interface point between the user s supply and the public system It is the re...

Страница 11: ...olt system with four conductors If the power source is to be used in countries with a higher or lower supply voltage the power source must be connected via a safety transformer Recommended fuse sizes...

Страница 12: ...ce has two outputs a positive terminal and a negative terminal for connecting welding and return cables The output to which the welding cable is connected depends on the welding method or type of elec...

Страница 13: ...e has fallen 5 6 MIG MAG and FCAW S welding An arc melts a continuously supplied wire The weld pool is protected by shielding gas For MIG MAG and FCAW S welding the power source is supplemented with w...

Страница 14: ...ungsten electrode is placed against the workpiece When the electrode is then lifted away from workpiece the arc is struck at a limited current level 12 15 A 5 8 MMA welding For welding with coated ele...

Страница 15: ...the welding power source is not clogged with dirt How often and which cleaning methods apply depend on the welding process arc times placement and the surrounding environment It is normally sufficient...

Страница 16: ...welding current is interrupted during welding Check whether the overloading protection has deployed indicated in the control panel Check the mains power supply fuses The overheating protection trips...

Страница 17: ...pean standards EN 60974 1 2 and EN 60974 10 It is the obligation of the service unit which has carried out the service or repair work to make sure that the product still conforms to the said standard...

Страница 18: ...DIAGRAM 0460 740 001 18 ESAB AB 2017 DIAGRAM...

Страница 19: ...DIAGRAM 0460 740 001 19 ESAB AB 2017...

Страница 20: ...e Origo Mig 4001i 0460 455 883 Welding power source Origo Mig 4001iw with cooling unit 0460 455 884 Welding power source Origo Mig 4001i A24 with control panel A24 0459 839 032 Spare parts list Origo...

Страница 21: ...SPARE PARTS LIST 0460 740 001 21 ESAB AB 2017 SPARE PARTS LIST Item Ordering no Denomination 1 0458 398 002 Dust filter...

Страница 22: ...B AB 2017 ACCESSORIES 0460 564 880 Trolley with two wheels 0460 565 880 Trolley with four wheels 0460 911 880 Mounting brackets 0460 946 880 Stabilizer kit for counter balance 0460 815 880 Shelf for f...

Страница 23: ...CoolMidi 1000 0456 855 881 Water flow guard 0 7 l min 0461 203 880 Installation kit water return flow guard 0465 720 002 ESAB ready mixed coolant 10 l 2 64 gal Use of any other cooling liquid than th...

Страница 24: ...5 m 10 m 15 m 25 m 35 m 0459 491 880 Remote control unit MTA1 CAN MIG MAG wire feed speed and voltage MMA current and arc force TIG current pulse and background current 0459 491 883 Remote control un...

Страница 25: ...ACCESSORIES 0460 740 001 25 ESAB AB 2017...

Страница 26: ...Henares MADRID Tel 34 91 878 3600 Fax 34 91 802 3461 SWEDEN ESAB Sverige AB Gothenburg Tel 46 31 50 95 00 Fax 46 31 50 92 22 ESAB International AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWI...

Отзывы: