4 INSTALLATION
0460 740 001
- 11 -
© ESAB AB 2017
Make sure that the welding power source is connected to the correct supply voltage and that
it is protected by the correct fuse rating. A protective earth connection must be made in
accordance with regulations.
Rating plate with supply connection data
NOTE!
The welding power source is designed for connection to a
400 volt system with four conductors.
If the power source is to be used in countries with a
higher or lower supply voltage, the power source must be
connected via a safety transformer.
Recommended fuse sizes and minimum cable area
Mig 4001i
Mains voltage
400 V 3 ~ 50 Hz
Mains cable area
mm
2
4 G 4 mm
2
Phase current
I
eff
16 A
Fuse
anti-surge
type C MCB
20 A
20 A
NOTE!
The mains cable areas and fuse sizes as shown above are in accordance with
Swedish regulations. For other regions, supply cables must be suitable for the
application and meet local and national regulations.