S0740 800 191/E080229/P78
-- 47 --
cu19_20_2
20AP2:6
TIG Gas valve
Gas valve 10YV1 is controlled by the processor on circuit board 20AP1. It can
be activated via service function no. 10.
20AP2:7
TIG HF starting device
The 10AP1 HF starting device is controlled by the processor on circuit board
20AP1. It is activated during the starting sequence until the arc strikes, or for a
maximum of 0.7 seconds. The voltage on the primary side of transformer
10TV1 is about 500 V, producing a secondary voltage of 10 -- 12 kV, if a 4
metre long welding torch is connected. If the welding torch is 16 metre the HF
spark is about 8 kV.
Due to electromagnetic interference regulations the energy in the HF ignition
spark is limited. The HF spark weakens with increasing length of the torch. The
HF ignition is satisfactory for welding torches up to 16 metres.
20AP2:8
TIG Starting
The welding torch trigger switch is supplied at 42 V AC. Closing the contact
activates IC1 and supplies a Low signal to 20AP1.
Содержание Aristo Arc 4000i
Страница 14: ...S0740 800 191 E080229 P78 Mig U4000i valid for serial number 803 xxx xxxx 14 cu19_00...
Страница 15: ...S0740 800 191 E080229 P78 15 cu19_00...
Страница 16: ...S0740 800 191 E080229 P78 Mig 4000i valid for serial number 803 xxx xxxx 16 cu19_00...
Страница 17: ...S0740 800 191 E080229 P78 17 cu19_00...
Страница 18: ...S0740 800 191 E080229 P78 Tig 4000i valid for serial number 803 xxx xxxx 18 cu19_00...
Страница 19: ...S0740 800 191 E080229 P78 19 cu19_00...
Страница 20: ...S0740 800 191 E080229 P78 Arc 4000i valid for serial number 803 xxx xxxx 20 cu19_00...
Страница 21: ...S0740 800 191 E080229 P78 21 cu19_00...
Страница 28: ...S0740 800 191 E080229 P78 28 ct32_15 15AP1 Component positions...
Страница 41: ...S0740 800 191 E080229 P78 20AP1 Component positions 41 cu19_20_1...
Страница 49: ...S0740 800 191 E080229 P78 49 cu19_20_2 20AP2 Circuit diagram...
Страница 54: ...S0740 800 191 E080229 P78 54 emptypage...