SECTION 3 Installation
ESP-400C Plasma Power Source
3-4
NOTICE
3.4.2 Input Conductors
•
Customer supplied
•
May consist either of heavy rubber covered
copper conductors (three power and one
ground) or run in solid or flexible conduit.
•
Sized according to the chart.
Input conductors must be terminated with
ring terminals.
Input conductors must be terminated with ring
terminals sized for ½" hardware before being
attached to the ESP-400C.
3.4.3 Input Connection Procedure
1.
Remove left side panel of the ESP-400C
2.
Thread cables through the access opening in
the rear panel.
3.
Secure cables with a strain relief or conduit
coupling (not supplied) at the access opening.
4.
Connect the ground lead to the stud on the
chassis base.
5.
Connect the power lead ring terminals to the
primary terminals with supplied bolts, washers
and nuts.
6.
Connect the input conductors to the line (wall)
disconnect.
1 Primary
Terminals
2 Chassis
Ground
3
Power Input Cable Access Opening (Rear Panel)
2
3
1
Содержание 0558001729
Страница 1: ...F 15 657 Jun 2005 Installation Operation and Maintenance for the ESP 400C Plasma Power Source...
Страница 6: ...ESP 400C Plasma Power Source Table of Contents iv This page intentionally left blank...
Страница 62: ...SECTION 6 Troubleshooting ESP 400C and 600C Plasma Power Sources 6 24 Schematic Diagram Drawing 3...
Страница 63: ...SECTION 6 Troubleshooting ESP 400C and 600C Plasma Power Sources 6 25 Schematic Diagram Drawing 4...
Страница 64: ...SECTION 6 Troubleshooting ESP 400C and 600C Plasma Power Sources 6 26 Schematic Diagram Drawing 5 Part1...
Страница 65: ...SECTION 6 Troubleshooting ESP 400C and 600C Plasma Power Sources 6 27 Schematic Diagram Drawing 5 Part2...
Страница 100: ...SECTION 6 Troubleshooting ESP 400C and 600C Plasma Power Sources 6 62 6 11 IGBT Driver Board PCB2 3 P N 38030 Drawing 2...
Страница 106: ...SECTION 7 Replacement Parts ESP 400C Plasma Power Source 7 6 7 5 Right Side View 11 1 7 8 9 8 7 6 10 2 3 4 5 10 12...
Страница 108: ...SECTION 7 Replacement Parts ESP 400C Plasma Power Source 7 8 7 6 Left Side View 1 3 4 5 6 5 8 7 9 10 11 x4...
Страница 110: ...SECTION 7 Replacement Parts ESP 400C Plasma Power Source 7 10 7 7 Top View...
Страница 112: ...SECTION 7 Replacement Parts ESP 400C Plasma Power Source 7 12 7 8 Back Inside View 2 1 4 2 3...
Страница 114: ...SECTION 7 Replacement Parts ESP 400C Plasma Power Source 7 14 7 9 Middle Cross Section 5 2 3 4 3 2 F8 F9 1...
Страница 118: ...SECTION 7 Replacement Parts ESP 400C Plasma Power Source 7 18 This page intentionally left blank...