5 OPERATION
0463 404 101
- 17 -
© ESAB AB 2018
5.3.3
Menu selection
Stop Run with step Run without step
Welding speed
X
X
X
Step welding off/on
X
Weld length
X
X
Distance between welds
X
X
Crater time
1)
X
X
Backfill length
2)
X
X
Preheat
3)
X
X
X
Voltage %
4)
X
X
Wire feed speed %
4)
X
X
1)
Pause time when the tractor stands still at the end of a step weld for power sources
equipped with crater functionality
2)
Reverses at the end of a step weld to fill up a crater
3)
Delayed start of the tractor compared to welding start
4)
Remote control of voltage or wire feed speed respectively, if an ESAB wire feeder with
adapter is connected. These parameters are not available when the tractor is powered
from a battery.
5.3.4
Selection of units of measure
On Miggytrac™ B5001 there is an option to select metric
(mm and cm) or imperial/US (inch) units of measure.
The selection is made in the
UNITS
menu, by first
holding the Menu button depressed for 4 seconds, then
selecting the preferred units by clicking the Menu button
repeatedly.
A LED for "METRIC" or "INCH" respectively in the
display indicates the current selection.
The menu is automatically locked after 10 seconds.