background image

Collegamenti elettrici / Electrical Connections / Connexions électriques / 
Elektrische Anschlüsse / Conexiones Eléctricas 

 

 

 

ESA elettronica S.p.A. 

Via Padre Masciadri, 4/A 
22066 Mariano Comense (CO) ITALY 
Tel. ++39.031757400 
Fax ++39.031751777 
Web: 

www.esa-automation.com

 

E-mail: 

[email protected]

 

 

Function: Pulse + Direction 

Differential input mode 

Single ended input mode 

Reset

/Reset

Pulse

/Pulse

Dir

/Dir

Pulse

0VDC

/Pulse

C
H

0

Direction

/Direction

0VDC

Reset *

/Reset *

0VDC

Not Connected

1

2

3

4

5

6

7

8

17

18

Pulse

0VDC

/Pulse

C
H

0

Direction

/Direction

0VDC

Reset *

/Reset *

0VDC

Not Connected

1

2

3

4

5

6

7

8

17

18

Pulse

Dir

Reset

* Connect only if the signal is configurated by software 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание EW Series

Страница 1: ...Rev 0 Date 10 06 2015 405 1300 233 0 EW INGRESSI USCITE EW INPUT OUTPUT EW ENTRÉES SORTIES EW EINGABE AUSGABE EW ENTRADAS SALIDAS Dimensioni Dimensions Dimensions Abmessungen Dimensiones EW600C ...

Страница 2: ... EW600 EW 1 Spegnere il EW Switch off EW Éteindre le EW Das EW ausschalten Apague el EW CLICK CLICK 1 2 3 Rimozione EW600 da terminale EW Removal from terminal EW600 EW Retrait du EW600 des terminaux EW Trennung vom Terminal EW600 EW Extracción del terminal EW600 EW 1 Spegnere il EW Switch off EW Éteindre le EW Das EW ausschalten Apague el EW 1 2 ...

Страница 3: ...Collegamenti elettrici Electrical Connections Connexions électriques Elektrische Anschlüsse Conexiones Eléctricas Spring connector 9 10mm 0 14 1 5 mm2 30 14 AWG 1 1 2 ...

Страница 4: ...t Z Reset Reset 0 9 Pulse A Up pulse Pulse 10 Pulse A Up pulse Pulse 11 0VDC 0VDC 0VDC 0VDC 12 Not Used B Down pulse Direction 13 Not Used B Down pulse Direction 14 0VDC 0VDC 0VDC 0VDC 15 Reset Z Reset Reset 16 Reset Z Reset Reset 1 17 OVDC 18 Not Connected Software configurable Reserved Do not connect Function Incremental Pulse Differential input mode Single ended input mode Pulse 0VDC Pulse C H ...

Страница 5: ... H 0 B B 0VDC Z Z 0VDC Not Connected 1 2 3 4 5 6 7 8 17 18 Z A B Connect only if the signal is configurated by software Function Up Down Differential input mode Single ended input mode Up pulse 0VDC Up pulse C H 0 Dn pulse Dn pulse 0VDC Reset Reset 0VDC Not Connected 1 2 3 4 5 6 7 8 17 18 Reset Reset Up Up Dn Dn Up pulse 0VDC Up pulse C H 0 Dn pulse Dn pulse 0VDC Reset Reset 0VDC Not Connected 1 2...

Страница 6: ...ww esa automation com E mail customer care esahmi com Function Pulse Direction Differential input mode Single ended input mode Reset Reset Pulse Pulse Dir Dir Pulse 0VDC Pulse C H 0 Direction Direction 0VDC Reset Reset 0VDC Not Connected 1 2 3 4 5 6 7 8 17 18 Pulse 0VDC Pulse C H 0 Direction Direction 0VDC Reset Reset 0VDC Not Connected 1 2 3 4 5 6 7 8 17 18 Pulse Dir Reset Connect only if the sig...

Отзывы: