Before connecting PV panels to
t
he DC
t
erminals, please make sure
t
he
polarit
y
is
correct
. Incorrect
polarit
y connection could damage
t
he
inverter.
�
Check short-circuit current of
t
he PV string. The total short-circuit
current
of
t
he
PV
string should be less than the inverter's maximum DC
current.
�
Connect
the positive and
negat
ive terminals from
t
he PV panel to positive ( +)
terminals
and
negative(
-) terminals on the
PV-Invert
er. Each DC terminal on Inverter
can
withst
and
11A.
♦
For
inst
ance, if
t
he positive pole of a
st
ring is
connect
ed
at
MPP
t
racker A and
the
string's
negat
ive
po
le at MPP tracker B, this is called a mixed
connect
ion,
the
inverter no longer fulfils the
requirement
s of
t
he EMC
Directive.
♦
Only
connect
strings at one
input
zone and never mix the
input
zones A and
B.
♦
High
volt
ages exist
w
hen the PV panel is exposed to
t
he sun. To reduce risk
of
elect
ric shock, avoid touching live components and treat
connect
ion
terminals
carefully.
Cable requirements
Product Model
Current
Area CSA
(
mm
2
)
ESA-3600
20A
2.5 4.0
ESA-5000
32A
4.0 6.0
5.6.6 Connect To The Battery
�
Before
connect
ing to
t
he
batt
ery, you
must
inst
all a separate DC breaker (not less
than
120A)
betw
een
t
he inverter and
batt
ery.
That
will ensure the inverter can be
securely
disconnected during
maintenance.
�
DANGER
Reversed polarity will damage the inverter!!!
�
It
is very important for system
safet
y and
efficient
operation
t
o use appropriate
cable
for
batt
ery
connect
ion. To reduce risk of injury, you much use
t
he
proper
recommended cable size, refer
t
o the
following;
Figure 18
A
Grade
Description
Value
A
O.D.
10-12mm
B
C.S.A.
10-25mm
2
C
Bare Wire Length
10mm
�
The
batt
ery must be installed in accordance
wit
h the
manufacturer'
s
instructions.
�
The MAX charge/ discharge current of
t
he inverter is
50A.
�
The
inverter'
s
batt
ery
rat
ed
volt
age is 48V. The
bat
tery series connection voltage
must
not
exceed 48V or it
w
ill damage
t
he
invert
er and void any
warranty.
Follow the below steps to implement the battery connection:
(1)
Check
t
he
bat
tery nominal voltage meets the inverter
spec.
(2)
Disconnect the breaker
bet
ween inverter and
battery.
(3)
Check
out
the polarity of
t
he
bat
tery and
t
he
inverter.
(4)
Terminate
batt
ery DC cables by means of
t
he lugs
provided.
(5) Screw
the DC cable
t
o the inverter's
bat
tery
input
terminal.
(6)
The
correct
batt
ery technology
m
ust be selected upon commission, so
t
hat
it
can
be
cont
rolled via the
BMS
Figure 19
C:
0
0
CNB
LJ
&
Shut Down And Turn Off The Isolator
·
Before Operating In This Housing!
.&.
NOTE
w
e recommend using the Solarshop
appoint
ed
lit
hium battery, because the
bat
tery
BMS communication has been designed to be compatible
wit
h
t
he Solarshop Hybrid
Inverter.
�
�
DANGER
Danger to life due to voltages!
Before you
inst
all the BAT.NTC, you must
t
urn off
t
he
invert
er, check all
t
he separate
breake
rs are off, and the inverter's LED is off. Then you can safely install
t
he BAT.NTC
terminal
t
o the
invert
er.
17