ESA 125T Скачать руководство пользователя страница 19

113170-01E 

17

 

www.desatech.com

 

 

 

SERVICE PROCEDURES

 

Continued

 

Note: 

Route hoses as shown in Figure 17, page 

12 or Figure 20 according to model. Hoses are 
not to touch photocell bracket.

 

6.

 

Replace control cover.

 

7.

 

Replace upper shell (see 

Upper Shell Removal

page 10).

 

 

Pump End

 

 
 

 

 
 

 

 

Insert

 

 

Rotor

 

Air Output Filter

 

Pump Plate

 

Blade 

Air

 

Intake 
Filter

 

Filter End

 

Cover

 

Cover

 

 

Air Hose

 

 

 

Barb 
Fitting

 

Figure 23 - Rotor Location

 

Gap Adjusting Screw

 

.003"/.004"

 

(.076-.101 mm)

 

Gap Measured

 

Figure 22 - Air Hose to Barb Fitting

 

 

PUMP ROTOR

 

(Procedure if Rotor is Binding)

 

1.

 

Remove  upper  shell  (see 

Upper  Shell  Re- 

moval

, page 10).

 

2.

 

Remove fan guard.

 

3.

 

Remove filter end cover screws using 5/16" 
nut driver (see Figure 23).

 

4.

 

Remove filter end cover and air filters.

 

5.

 

Remove pump plate screws using 5/16" nut- 
driver.

 

6.

 

Remove pump plate.

 

7.

 

Remove  rotor,  insert  and  blades  (see 
Figure 23).

 

8.

 

Check for debris in pump. If debris is found, 
blow out with compressed air.

 

9.

 

Install insert and rotor.

 

10.

 

Check gap on rotor. Adjust to .076/.101 mm 
(.003"/.004") if needed (see Figure 24). 

Note: 

Rotate rotor one full turn to ensure the

 

gap is .076/.101 mm (.003"/.004") at tightest

 

position. Adjust if needed.

 

11.

 

Install blades, pump plate, air filters and filter 
end cover.

 

12.

 

Replace fan guard and upper shell (see 

Upper 

Shell Removal

, page 10).

 

13.

 

Adjust  pump  pressure  (see 

Pump  Pressure 

Adjustment

, page 10).

 

With Feeler 
Gauge

 

Rotor 

Blade

 

Gap Adjusting Screw

 

 

Figure 24 - Gap Adjusting Screw 

Locations

 

 

Sandpaper

 

 

 

 

Figure 25 - Sanding Rotor

 

IGNITION CONTROL ASSEMBLY

 

 

WARNING: High voltage!

 

1.

 

Unplug heater.

 

2.

 

Remove control cover screws (2) using phil- 
lips  screwdriver  to  expose  ignition  control 
assembly (see Figure 11, page 10).

 

3.

 

Remove fuse from fuse holder.

 

4.

 

Replace  with  new  fuse  (DESA  Heating 
Prod-  ucts  part  number  113752-01).  Do  not 
substitute  a    fuse  with  a  higher  current 
rating.  Use  an equivalent 6.3 amp time lag, 5 
x 20 mm fuse.

 

5.

 

Replace  control  cover  (see  Figure  11, 
page 10).

 

Fuse Holder

 

Note: 

If rotor is still binding, proceed as follows.

 

14.

 

Perform steps 1 through 6.

 

15.

 

Place fine grade sandpaper (600 grit) on flat 
surface.  Sand  rotor  lightly  in  “figure  8” 
motion four times (see Figure 25).

 

16.

 

Reinstall insert and rotor.

 

17.

 

Perform steps 10 through 12.

 

Fuse

 

 
 
 

 

 
 
 

Figure 26- Replacing Fuse

 

Содержание 125T

Страница 1: ...ct Identification 3 Theory of Operation 4 Ventilation 4 Assembly 4 Operation 5 Operation with Portable Generator 7 Storing Transporting or Shipping 7 Preventative Maintenance Schedule 8 Troubleshooting 8 Service Procedures 10 Specifications 15 Wiring Diagrams 16 Technical Service 17 Replacement Parts 17 Accessories 17 Illustrated Parts Breakdown and Parts List 18 Warranty and Repair Service 28 Fill ...

Страница 2: ...include pregnant women persons with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes Make certain you read and understand all warn ings Keep this manual for reference It is your guide to safe and proper operation of this heater 1 Use only kerosene 1 2 diesel fuel oil JET A or JP 8 fuels to avoid risk of fire or explosion Never use gasoline naphtha pain...

Страница 3: ... combustible materials 8 feet 244 cm from hot air outlet 6 feet 183 cm from top and 4 feet 120 cm from sides and inlet 7 Locate heater on a stable and level surface while hot or operating or a fire may occur 8 Use only in well vented areas Before using heater provide at least a 2800 square cm three square foot opening of fresh outside air for each 30 kw 100 000 Btu Hr of rating 9 Keep children and ...

Страница 4: ...is damaged promptly inform dealer where you bought heater FUELS WARNING Use only kero sene 1 2 diesel fuel oil JET A or JP 8 fuels to avoid risk of fire or explosion Never use gasoline oil drained from crankcases naphtha paint thinners alcoholorotherhighly flammable fuels Use only kerosene 1 2 diesel fuel oil JET A or JP 8 fuels Heavier fuels such as No 2 fuel oil or No 2 diesel fuel may also be use...

Страница 5: ...ir if more heaters are being used The minimum ventilation requirements must be followedtoavoidrisksassociated withcarbonmonoxidepoisoning Make certain these requirements are met prior to operating heater Example A 58 6 kw 200 000 Btu Hr heater requires one of the following a two car garage door 4 88 meter 16 feet opening raised 12 7 cm 5 inches a single car garage door 2 74 meter 9 feet opening ra...

Страница 6: ...d three wire extension cord Extension cord must be at least six feet 1 8 meters long Extension Cord Size Requirement 6 to 10 feet 1 8 to 3 meters long use 18AWG 0 75 mm2 rated cord 11 to 100 feet 3 3 to 30 5 meters long use 16 AWG 1 0 mm2 rated cord 101 to 200 feet 30 8 to 61 meters long use 14 AWG 1 5 mm2 rated cord 6 Plug extension cord into standard 120 volt 60 hertz 3 prong grounded outlet 7 T...

Страница 7: ...hock can occur LOGIC ENHANCED IGNITION These models have an electronically controlled ignition system that is able to detect problems during startup and is able to apply an automatic choke to increase the likelihood of ignition If the heater does not ignite within the first second the motor will slow down momentarily If your heater does not light after the first choke it will repeat once If the heat...

Страница 8: ... the generator Refer to Operation page 5 for starting stopping and resetting heater procedures Alternator STORING TRANSPORTING OR SHIPPING Note If shipping transport companies require fuel tanks to be empty 1 Remove drain plug from bottom side of fuel tank and drain all fuel 2 Replace drain plug 3 If any debris is noted in old fuel add 1 or 2 quarts of clean kerosene to tank stir and drain again T...

Страница 9: ...ubricated TROUBLESHOOTING WARNING Never service heater while it is plugged in operating or hot Severe burns and electrical shock can occur FAULT CONDITION Motor does not start five seconds after heater is plugged in INDICATOR LIGHT Ignitor POSSIBLE CAUSE 1 No power to heater 2 ON OFF switch not in the ON position 3 Thermostat setting is too low REMEDY 1 Check circuit breaker in elec trical panel 2 ...

Страница 10: ...08V or 9 Check for proper line voltage above 132v Heater ignites but ignition control assembly shuts heater off after a short period of time INDICATOR LIGHT Flame 1 Pump pressure incorrect 1 See Pump Pressure Adjust ment page 10 2 Dirty air intake air output 2 See Air Output Air Intake and and or lint filter 3 Dirty fuel filter 4 Obstruction in nozzle Lint Filters page 10 3 See Fuel Filter page 11 4...

Страница 11: ...tput Air Intake and Lint Filters IMPORTANT Remove fan from motor shaft before removing motor from heater The weight of the motor resting on the fan could damage the fan pitch see Figure 8 1 Remove upper shell see Figure 7 2 Use 1 8 allen wrench to loosen setscrew which holds fan to motor shaft 3 Slip fan off motor shaft 4 Clean fan using a soft cloth moistened with kerosene or solvent 5 Dry fan th...

Страница 12: ......

Страница 13: ... 12 Adjusting Pump Pressure FUEL FILTER 1 Unplug heater 2 Remove control cover screws using medium phillips screwdriver 3 Remove control cover 4 Pull upper fuel line off fuel filter neck see Figure 13 5 Carefully pry bushing fuel filter and lower fuel line out of fuel tank see Figure 13 6 Wash fuel filter with clean fuel and replace in Figure 14 6 Remove combustion chamber Stand com bustion chamber o...

Страница 14: ...12 113170 01E www desatech com Figure 14 Disconnecting Ignitor Wires from Ignition Control Assembly 170T Model Shown ...

Страница 15: ...fuel line hose and air line hose to nozzle adapter assembly See Fuel and Air Line Replacement and Proper Routing page 13 14 Replace photocell in photocell bracket Route wires as shown in Figure 17 Figure 16 Ignitor HA1100 Replacement NOZZLE ASSEMBLY 125T and 170T Models Only 1 Remove upper shell see Upper Shell Re moval page 10 2 Remove fan see Fan page 10 3 Remove fuel and air line hoses from noz...

Страница 16: ...14 113170 01E www desatech com Assembly ...

Страница 17: ...Replace fan see Fan page 10 13 Replace upper shell see Upper Shell Removal page 10 Nozzle Face Nozzle Sleeve Nozzle Face Nozzle Nozzle Adapter Nozzl e Sleev e Nozzle Adapter Nozzle Adapter Bracket Air Line Fitting Fuel Line Fitting Nozzle Air Line Fitting Fuel Line Fitting Figure 19 Nozzle and Nozzle Adapter 200T Model Only 1 Remove combustion chamber and ignitor by following steps 1 through 7 und...

Страница 18: ...igure 20 according to model and from fuel filter see Fuel Filter page 11 If air line hose is damaged disconnect from nozzle adapter see Figure 17 page 12 or Figure 20 according to model and from barb fitting on pump end cover see Figure 22 page 14 5 Install new air and or fuel line Attach one end of air line hose to barb fitting on pump end cover see Figure 22 page 14 and the other end to nozzle adap...

Страница 19: ...004 if needed see Figure 24 Note Rotate rotor one full turn to ensure the gap is 076 101 mm 003 004 at tightest position Adjust if needed 11 Install blades pump plate air filters and filter end cover 12 Replace fan guard and upper shell see Upper Shell Removal page 10 13 Adjust pump pressure see Pump Pressure Adjustment page 10 With Feeler Gauge Rotor Blade Gap Adjusting Screw Figure 24 Gap Adjustin...

Страница 20: ... 0 6 2 Electric Requirements 120 V 60 HZ 120 V 60 HZ 120 V 60 HZ Amperage Normal Run 3 6 3 6 3 6 Maximum Motor Speed RPM 3400 3400 3400 Hot Air Output CFM 520 580 600 Motor Horsepower 1 5 1 5 1 4 Shipping Weight 81 36 74 82 37 2 87 39 46 Approximate Pounds Kilograms Heater Weight without Fuel 73 33 11 74 33 57 79 35 86 Approximate Pounds Kilograms Use of 2 diesel fuel oil will result in noticeable...

Страница 21: ...113170 01E 1 9 www desatech com ...