6 - STORAGE
6 - A - UNDER 3 MONTHS
)
A sealed package (eg. heat-sealed plastic) to avoid dust and projections.
6 - B - 1 YEAR MAXIMUM
)
Drain compressor oil carefully.
)
Dismount the 1st and 2nd stage cylinder heads.
)
Clean cylinder heads and valves carefully.
)
Inject storage oil into the cylinder heads and valves.
)
Mount the cylinder heads.
)
Fill the compressor with storage oil.
)
Start the compressor and run for 10 min off load; introduce 20cl of oil into
the compressor air intake.
)
A sealed package (long term) category 4C with dehydrating packs, conforming to
S.E.I. norms.
6 - C - ABOVE 1 YEAR
Every year
)
Drain storage oil carefully.
)
Fill up with new storage oil.
)
Start the compressor and run for 10min off load
)
Start the compressor and run for 10min on load.
)
A sealed package (long term) category 4C with dehydrating packs, conforming to
S.E.I. norms.