12
DIP
Modes and functions
Option
Effect
DIP1
OFF
DIP2
Advance warning
ON
the flashing light comes on and the operation begins after a 3
second warning
OFF
the flashing light comes on and the operation begins
immediately
DIP3
Key commands using ST1 and ST2
ON
ST1: opening command; ST2: closing command
OFF
ST1: opening and closing commands; ST2: no function
DIP4
Automatic or step-by-step mode
ON
automatic mode (the barrier closes automatically once standby
time has passed, adjusted using T.E.)
OFF
step-by-step mode (the barrier only closes when receiving the
key command)
DIP5
Automatic mode optional
(only if DIP4 = ON)
ON
during standby, the barrier obeys the key commands (can be
closed before standby time finishes)
OFF
the barrier cannot be closed until standby time finishes; key
commands will cause standby time to restart
DIP6
Opening photocell testing
ON
testing enabled
OFF
testing disabled
DIP7
Encoder
ON
encoder enabled
OFF
encoder disabled
DIP8
Interlocking mode (with FT1)
ON
interlocking mode enabled: the barrier closes if SG.C is enabled
during standby time (in automatic mode)
OFF
interlocking mode disabled
DIP9
Closing photocell testing
ON
testing enabled
OFF
testing disabled
DIP10 No function
always place in OFF
Function and mode selection using SW2 (DIP1 = OFF)
T.LG: fan operation time
Regulate the time the operator cooling fan is working.
•
Minimum value: 3 seconds; maximum value: 90
seconds
T.E: barrier open standby time
If automatic or optional automatic operation mode has
been programmed, adjust T.E. to set standby time with
the barrier open (before starting to close automatically).
•
Minimum value: 0 seconds; maximum value: 90
seconds
P.M: motor torque
Use P.M. to adjust the maximum motor power value.
Torque adjustment, respecting the maximum
closing forces set out in Standard EN12453:2000.
Make the measurements as described in Standard
EN 12445:2000.
Potentiometer adjustment