10
Changing side
Right barrier
Left barrier
45º
THE BARRIER MUST BE BALANCED FOR
PROPER OPERATION.
•
Unlock the operator and tighten the spring until
the barrier is balanced at 45°.
Balancing
Unlock
NTS
324E, NTS
424E, NTS
624E:
230Vac/
50Hz
NTS
324EM, NTS
424EM, NTS
624EM:
125Vac/
60Hz
CHG
BAT: (2x12V)
BATTERY
IN/OUT
General connections
D1 and D2:
CL
(static)
Barrier closed
CL
(flashing)
Barrier closing
OP
(static)
Barrier open
OP
(flashing)
Barrier opening
XX
(countdown)
Barrier on standby
STOP
Operator unlocked
PA
(static)
Pause (operation not complete)
rS
(static)
Barrier searching for close position
D3 and D4:
C5
Closing safety device
activated
E1
Encoder motor halted
F1
Thrust limit exceeded
bA
Battery working
Ftço
Photocells defective
(testing)
Display indications