M
antenimiento_0
3 v1.3.fm
- 2
9/2/0
8
48
Installation manual
MAINTENANCE AND DIAGNOSIS OF FAILURES
1
MAINTENANCE
Before carrying out any maintenance
operation, disconnect the device from the
power supply.
1
Frequently check installation in order to discover any
imbalance all signs of deterioration or wear. Do not
use the device if any repair or adjustment is
necessary.
2
Clean and lubricate the articulations and rails of the
gate, so as not to increase the effort of the operator.
3
Check that the transmitters and photocells, as well
as their installation, have not suffered any damage
from the weather or external agents.
2
FAILURE DIAGNOSIS
3
SCRAP
The operator, up until the end of its useful life,
must be dismounted at its location by an
installer who is as well qualified as the person
who completed the assembly, observing the
same precautions and safety measures. In this
manner we will avoid possible accidents and
damage to adjacent facilities.
}
The operator must be deposited in the appropriate
containers for subsequent recycling, separating and
classifying the different materials in line with their
nature. NEVER deposit it in domestic rubbish or in
landfills which are not controlled, as this will cause
environmental damage.
4
SPARE PARTS
If the operator needs repairing, go to an
authorised assistance centre or manufacturer;
never try to repair it yourself.
Use only original spare parts. See the figure
“Content and spare parts” on page 39.
Problem
Cause
Solution
The operator does not
make any movement when
the opening or closing
controls are activated
Absence of system power voltage
Re-establish the power supply voltage
Defective electrical installation
Check that the installation does not
present any short-circuits or cut-off
points
Defective control panel or control
devices
Check these elements, seeing their
respective manuals
By activating the opening
or closing controls, the
operator is enabled but the
gate does not move
Gate obstructed or blocked
Unblock, adjust and lubricate the gate
articulations
The angle formed by the two sections
of the articulated arm is too big or too
small
Carry out installation again, respecting
the dimensions indicated in the “Fig. 5
Example of assembly position for
operator with articulated arm”
The gate moves in an
irregular manner
Gate partially obstructed or blocked
Unblock, adjust and lubricate the gate
articulations
The gate cannot
completely close (or open)
The photocell detects an obstacle
Eliminate the obstacle and try again
T h e r e s i s t a n c e o f t h e g a t e h a s
increased when closing (or when
opening)
Check the moving parts of the gate and
eliminate the resistance
The force of the operator during
closing (or opening) is too low
Using the control panel programme,
increase the closing or opening force
The mechanical stoppers of the gate
or the operator are maladjusted
Adjust the stoppers
CICLON.book Page 48 Friday, April 11, 2008 2:34 PM