background image

NOTE 2

 : The memory capacity is of 21 transmitter keys. This means that a 2 key transmitter 

needs  2  memory  positions.  It  is  possible  to  display  the  memory  position  by  following  the 
procedure 10. 

A transmitter key can be memorized on each relay RR or RV but not on both.

10 - Display of the transmitter memory position

With this procedure it is possible to display the position occupied by a given transmitter key.

1)  Push  the  transmitter  key  for  which  you  need  to  know  the  memory  position  and  verify the 
activation of the relay and the led.
2) Push the button 

PR

 of the receiver for 1 second.

At this point begins a sequence of 7 lightings of the two led LR and LV: by taking a note of what 
color light blinks, it is possible to get the memory position, according to the  table 1:

Led flash

1

2

3

4

5

6

7

Green LED

1

2

4

8

16 32 64

Red LED

0

0

0

0

0

0

0

Example

:

 

Transmitter blinks the following seven times after pushing the red relay (PR) key: 
RED  -  RED  -  GREEN  -  GREEN  -  RED  -   RED  -   RED 
This corresponds to the 12th position.

11 - Overwrite of an already stored Transmitter code 

1 - Determine transmitter key memory position ( see paragraph 10 )
2 - Press corresponding relay programming key 

PR

 or 

PV 

on receiver for 

4 seconds

.

3 - Within 2 seconds press 

PV

 : the led switches off.

4 - Within 2 seconds enter the transmitter memory position of existing transmitter by using ( 

PR red

 ) and ( 

PV green

) accordingly Tab. 1. There must be a total combination of seven 

button pushed ( PV or PR) to match the memory position of existing transmitter.
5 - Within 1 second press the new transmitter key to be programmed.

The previous transmitter key will be removed and replaced by the key pressed in step 5.

12 - Memory capacity display

This procedure allows to display the number of occupied memory positions.

1) Push the button 

PV

 of the receiver for 1 second.

At this point the receiver begins a sequence of 7 lightings of the leds LR and LV.  Referring to that it 
is possible to obtain the number of the occupied memory positions, according to tab.1

13 - Memory full

When the receiver memory is full and a memorization procedure is started,  both the leds LV and 
LR  blink 3 times.

14 -  Total memory erasure

1) Keep on pushed 

PR

 of the receiver until the red led LR is turned on.

 

2) Keep

 

on pushed simultaneously 

PV

 and

 PR

 for 

4 sec

.   The receiver will give the operation 

confirmation with 3 blinks of the leds LV and LR.

15 - Relay configuration display

Keep on pushed 

PR (or PV)

 of the receiver for 4 sec. The current configuration of the relay is 

displayed by the corresponding led, according to table 2 :

16 - Relay programming

The relays can be programmed in all the 3 modes ( pulse, step or delayed), but the following 
combinations : 

Not allowed configurations

Red relay (RR)

Green Relay (RV)

 Step

Delayed

Delayed

Delayed ( with different delay time )

17 - Relay RR (RV) configuration 

- (Fig. 4)

The operating mode of the relay is cyclic. See below to change the mode 

-If the relay is set as pulse:

it becomes latching and after timed;

-If the relay is set as latching:

it becomes pulse;

-If the relay is set as timed:

it becomes pulse.

Operating mode ( RR or RV )

Pulse mode

Continuous light

Step mode

Slow blinking

Delayed mode

Fast blinking

Led light type (LR or LV)

Fig. 5

1

1

1

PR

PV

PR

PR

PR / PV

PR

18 - Relay  RR ( RV) timing settings 

-( Fig. 5)

The time settings of the delayed relay can be done only if the relay has been previously set as 
pulse.
Push the button 

PR

 

(PV)

 of the receiver for 

4 sec

.;the led LR (LV) will turn on and will display the 

present operating mode of the relay RR (RV). If the led blinks slow or fast push again 

PR

 for 

sec.

 and the relay will be set as pulse. Then push 

PR

 for 

1 sec.

 and the led LR (LV) switches off. 

Then, within 2 seconds, begin to set the selected relay time, by pushing on the buttons PR and 
PV according to Table 4 and considering that PR has weight of "0" while PV has weight "1". 

NOTE

The last pressures on PR of the sequence are not necessaries.

Example 1: 8 sec. delay : input the sequence : PR - PR - PR - PV - PR - PR - PR.
Example 2: 2 min delay.: input the sequence : PV - PR - PR - PR - PR - PR - PV.

Fig. 4

1

1

1

PR / PV

PR

Pulse

Step

Delayed

Step

Pulse

Pulse

PR

PR

19 -

 Jumper J1 and J2 settings

The jumper J1 and J2 allow to set the operating mode of the receiver when it replies to the 
transmitter.  
Once received the second signal by the transmitter, the receiver sends back the “Status signal” 
to communicate the transmitter the status of the relays or the auxiliary inputs.
The information sent contains the status of the relays ( which can be in step or pulse/delayed 
mode ) or the inputs which can be open or closed.
The message is different depending upon the jumper J1 and J2.
Before to send the message, the receiver does a test on the status of the relays RR and RV and 
the inputs connected at the terminals 1,2, 3)
With the information  received by the receiver, the transmitter switch on the led green or red and 
the buzzer. Refer to table 5 to know the status of the relays / inputs by the colour of the  led and 
the bip of the buzzer. 

NOTE : 

When the receiver sends the logic level of the auxiliary inputs ( jumper J1, J2 OPEN), 

the message is sent to the transmitter with a delay of 4 sec. to allow the security appliances 
connected to change their status.The status of the inputs ( I1-C and I2-C ) is monitored by the 2 
led L1 and L2.

Logic level of input at terminal 1-3

Logic level of input at terminal 2-3

Status relay RR

Status relay RV

Current configuration

Final configuration

IS-RTWERUK Rev. 3 del 13.06.2017

Manufactured by CDVI Wireless Spa

Via Piave, 23 - 31020 

San Pietro di Feletto (TV) - Italy

Tel: +39.0438.450860 - Fax: +39.0438.455628

e-mail: 

 

Web: www.erone.com

[email protected]

T H E S M A R T L I V I N G

The guarantee period of the product is 24 months, beginning from the manufacturer date. 
During this period, if the product does not work correctly, due to a defective component, the 
product will be repaired or substituted at the discretion of the producer. The guarantee does not 
cover the plastic container integrity. After-sale service is supplied at the producer's factory.

GUARANTEE

Tab 4

Pressioni tasti / Button act /

 

Tastenbetatingung/                    

1°      2°      3°     4°     5°     6°     7°

Presion botones

sec/sec./sek/seg.                       1       2       4       8    16       R       R
sec/sec./sek/seg.                     10     20     40     80   160      V       R
Min/min/min/min                      2       4       8     16     32       R      V
Min/min/min/min

                   

20     40      80   160  320       V      V

Tab. 1

Tab. 2

Tab. 3

J1

J2

Jumper 
Open

Jumper 
Closed

OPEN

CLOSED

BUZZER TX

LED TX

1 BEEP

2 BEEP

RED

GREEN

OPEN

CLOSED

BUZZER TX

LED TX

1 BEEP

2 BEEP

RED

GREEN

 PULSE

STEP

BUZZER TX

LED TX

2 BEEP

( on )

BEEP 

GREEN

GREEN

BUZZER TX

LED TX

2 BEEP

( on ) 

BEEP 

GREEN

GREEN

Tab. 5

 PULSE

STEP

( off )

BEEP 

RED

( off )

BEEP 

RED

Hereby, CDVI Wireless Spa, declares that the radio equipment type 

 is in compliance with directive 2014/53/EU. The full text of the EU 

declaration of conformity is available at the following internet address: www.erone.com.

SEL2641R433-TW

S2TR2641TW