ENGLISH
The receiver Erone 400 W is a radio programmer which can drive
directly an asynchronous 230 Vac AC motor with max power of
400 W. The operating frequency and the coding system are
different, depending upon the model.
The following table summarises the range of radio programmers,
pointing out series, frequency and coding system:
SERIES
TYPE
FREQUENCY
CODING
ERONE 024A
SEL 2641R433P4
433.92 MHz
Rolling code
ERONE 30(DP/SL) SEL 39R30P4
30.875 MHz
Dip/Self learning
ERONE DS433
SEL 39R433P4
433.92 MHz
Dip-switch
ERONE 028A SEL 2681R868P4
868.30 MHz
Rolling code
Depending upon the frequency and the coding, the receiver
operates with different transmitters, according to the following
table:
Receiver Type
Usable transmitter
SEL 2641 R433P4
S2TR2641E2/E4
SETR2641AM2
SETR2641-TM
SEL2681 R868P4
S2TR2681E2/E4
SEL 39 R433P4
SETDS39433 E2/E4
SEL39 R30P4
SETL 39E2/E4
SETD 39E2/E4
1 - INTRODUCTION
Type
SEL 2641R433-P4 / SEL2681R868-P4
Receiver type
Carrier frequency
433,92 / 868,30 MHz
Local oscillator frequency
6,6128 / 13,399 MHz
Modulation
AM/ASK
Input load
50 Ohm
Channel width
> 25 KHz
Intermediate frequency
10,7 MHz
Input sensitivity
-115 dBm
Local oscillator emissions
< -57 dBm
Power voltage
230 Vac
Motor maximum power
400 W
Memory capacity
85
Operating temperature
-20°/+70°C
IP grade
IP44
Weight
380 gr.
Overall dimensions
140 x 115 x 52 mm
Superheterodyne
Type
SEL 39R433-P4 / SEL39R30-P4
Receiver type
Superheterodyne
Carrier frequency
433,92 / 30,875 MHz
Local oscillator frequency
6,6128 / 30,420 MHz
Modulation
AM/ASK
Input load
50 Ohm
Channel width
> 25 KHz
Intermediate frequency
10,7 Mhz / 455 KHz
Input sensitivity
-115 / -117 dBm
Local oscillator emissions
< -57 dBm
Power voltage
230 Vac
Motor maximum power
400 W
Memory capacity
100
Operating temperature
-20°/+70°C
IP grade
IP44
Weight
380 gr.
Overall dimensions
140 x 115 x 52 mm
2 - TECHNICAL SPECIFICATIONS
4 - INSTALLATION
3 - FUNCTIONALITY
Sequential (or cyclic):
1 Pulse opens
1 Pulse closes, stop with a timer
Mixed
1 Pulse opens, closing only with permanent contact.
Man present:
Opening and closing only with permanent contact (reduced
range). The motor time-out is selectable (from 6 to 186 sec) by
means of 5 dip - switches; it is used as security to avoid powering
the motor for too long after the mechanical stop.
Other features:
Local and general operating selection (with multiple motor
driving); the general command is possible only for the sequential
operating mode.
For the general mode using it is necessary to use a 4 keys
transmitter of the same range.
It possible to connect an external push button or a key - contact to
complete the radiocontrol.
The memory capacity is 85 or 100 transmitters.
Positioning
The local choice is very impotant for the best result of the installation.
The following conditions have to be followed:
- Fix the radioprogrammer far from the interference sources as
informatic systems, alarm systems or other radio emissions.
- The distance between 2 receivers should be greater of 1.5 mt.
Fixing
Remove the cover of the receiver; fix the box in each corner by
using the screws and the plugs supplied.
Connections
1
- Connect the power supply (230 Vac) to the terminal blocks (fig.
10):
terminal 1 = PH phase
terminal 2 = N neutral
terminal 6 = earth
Ph
1
2
6
N
3
4
5
7
C
O CL
Fig. 11
Fig.10
2
- Connect the motor to the terminal blocks (fig. 11):
terminal 3 = C common
terminal 4 = O open
terminal 5 = CL close
terminal 7 = GND ground
Connect the capacitor between terminals 4 and 5.
Pag. 7