Installation
All connections are shown on
Figure 1
at the fold-out page at the back of this manual.
Carefully follow the instructions in order not to cause mal-function, damage to the
equipment or humans. Incorrect installation will void the warranty and repairs will
consequently be invoiced according to current scale charges.
All settings are selected remotely using the
S111SX Node Manager
- no on-board settings
are required or even possible.
Once all cable connections have been done installation is completed by activating the mains
switch. Prior to activating the mains switch make sure the S111SX Node Manager is running
and connected to the network.
If several R131VX units are present carefully note the exact time of mains switch activation -
this information is crucial when identification and configuration of each unit later is carried
out using the S111SX Node manager.
Warning:
Self-test procedures, including moving the pan & tilt head to end-stops, are
initiated when the calibrate function is activated from the S111SX Node Manager. Make sure
all connections and adjustments, including setting the pan & tilt end-stops and/or limit
switches are made prior to activating the calibrate function.
Unpacking the unit
Check that the carton box contains the following items:
v
R131VX unit
v
Connector kit
v
Box mounting kit
v
Installation Manual (this manual)
Carefully check for any sign of damage. Any such damage or parts missing should be
reported to your supplier prior to installation.
Box installation
The box must be mounted on a plane surface to prevent the box from being twisted and
thereby become leaky. The box should be oriented with the cable glands pointing
downwards.
Fit the plastic mounting ears on the box. The mounting ears and screws are enclosed in the
box mounting kit.
Drilling pattern: 203 mm (width) x 329 mm (height). For further details refer to
Figure 2
at
the back of the fold-out page.
Cable glands
All cables are fed through the cable glands. For each cable choose an appropriate sized
gland according to the table below close to the connector inside. Make sure to tighten the
glands properly. For further details refer to
Figure 2
at the back of the fold-out page.
Cable diameter ø6-12 mm
Cable gland, Type 2
Cable diameter ø5-9 mm
Cable gland, Type 1