background image

Twisted Pair Cable Specifications

The cables are the most important part of a Twisted Pair Video installation, and the overall
performance and transmission distance, depends on the selected twisted pair cable.

Please note, that twisted pair cables with stranded conductors are NOT suitable - 
the conductors must be solid.

When shielded cables are used the transmission distance might be considerably lowered,
due to the higher capacitance introduced by the shield - carefully study the specification
on the actual cable and compare them with the table below. The choice between shielded
and unshielded cable will always be a compromise between transmission distance and
immunity towards noise and crosstalk.

pcs./m

5

Twists

dB/km

30-36

Attenuation @ approx. 5 MHz

nF/km

90

Capacitance

130

120

100

Characteristic impedance @ <1 MHz

mm

1

0,6-0,8

0,5

Solid conductors, diameter (ø)

Unit

Max.

Typ.

Min.

Description

Suitable cable types:

Standard Category 5e.

Belden 1700A.

Belden 1872A.

Mödinger A-2Y(L)2Y / 2x2x0,6 (2 pairs).

Note: When using cables including several not individually screened pairs, it is, as a
general rule, not recommended to use more than one pair per cable, in order to avoid
possible crosstalk.

Note: When using cables including several not individually screened pairs, do not mix long
and short cable distances, in order to avoid possible crosstalk.

Note: Avoid locating unscreened twisted pair cables parallel to high speed data cables,
mains cables, or other cables with high energy and/or high frequency signals.

EMC/EMI

All electronic equipment can emit, or be sensitive to, induced electromagnetic noise which
can be conducted by the connected wires, or transmitted as electromagnetic fields.
Electromagnetic noise can cause malfunction or damage to the equipment.
The Series 230 fulfils the relevant EMC standard (refer to specifications) and is therefore
CE labelled.

WARNING: The stated approvals, and other specifications are valid only if
the equipment is installed according to the instructions in this manual.

2800-00087

Содержание 230/3 Series

Страница 1: ...RNITEC DENMARK H RK R 24 DK 2730 HERLEV DENMARK PHONE 45 44 50 33 00 FAX 45 44 50 33 33 E MAIL info ernitec dk ERNITEC UK PHONE 44 0 1903 77 27 27 FAX 44 0 1903 77 27 07 E MAIL info ernitec co uk ERNI...

Страница 2: ...also be used with standard 120 ohm twisted pair cable suited for video transmission Types like the Belden 1872A or 1700A can also be used On the receivers and repeater the twisted pair input is galva...

Страница 3: ...rovided cable clip inside the Series 230 box The figure below shows how the mains cable should be routed Mains terminal block Cable clip Mains cable Mains cable WARNING Make sure the equipment is eart...

Страница 4: ...the monitor Remember to set the monitor termination to 75 ohm 4 If a negative or turned over picture is displayed swap the twisted pair input on the receiver 5 Check that the green SYNC LED on the rec...

Страница 5: ...le types Standard Category 5e Belden 1700A Belden 1872A M dinger A 2Y L 2Y 2x2x0 6 2 pairs Note When using cables including several not individually screened pairs it is as a general rule not recommen...

Страница 6: ...30 1GV 3 BVX 230 1GV 3 receiver part dB 36 CMMR Weighted dB 66 Signal noise ratio 5 MHz dB 6 3 0 Equalisation 2dB Hz 10 M 25 Frequency response Balanced 110 Vpp 4 2 Voltage Video Output 1Vpp in BVT 23...

Страница 7: ...ir cable BVT 230 BVR 230 2 Vpp 3 Vpp 3 dB 5MHz 4 Vpp 6 dB 5MHz 600 m 900 m 900 m P1 Bal output voltage CAT5E 24AWG 0 5mm 2 Vpp 3 Vpp 3 dB 5MHz 4 Vpp 6 dB 5MHz 1000 m 1500 m 1500 m P1 Bal output voltag...

Страница 8: ...0498 00082 V0 1 0498 00082 V0 1 BVT230 BVT230 ernitec ernitec PWR OUT VIDEO VIDEO IN J3 J1 J2 BAS POS 2 3 4Vpp POS 1 2 3Vpp OPEN 2Vpp P1 230VAC max 25mA 45 60Hz 2 Vpp 3 Vpp 3 dB 5MHz 4 Vpp 6 dB 5MHz 6...