Orion/2 Outdoor
34
•
SEQUENCE LINE
There are eight sets of sequence lines built in the dome camera. Using
LEFT/RIGHT direction keys to select a line first and then set its sequence points.
•
SEQUENCE POINT
Up to 32 points can be specified for each sequence line. The sequence points
represent the orders of the preset points that the dome will automatically run, and
the bellowing setup items; PRESET POSITION, SPEED, and DWELL TIME, are
related to this item.
•
PRESET POSITION
Users can assign a specific preset position to the selected sequence point with
this item.
•
SPEED
Users can set the Speed that the dome goes to the next sequence point, and the
setup speed range is from 1 ~ 15. Refer to below table for more information.
PAN
(degree/sec.)
TILT
(degree/sec.)
Speed 1
10
8
Speed 2
23
12
Speed 3
35
22
Speed 4
45
30
Speed 5
55
40
Speed 6
65
50
Speed 7
75
58
Speed 8
185 185
Speed 9
205 210
Speed 10
225 240
Speed 11
250 275
Speed 12
280 305
Speed 13
320 335
Speed 14
365 365
Speed 15
400 400
SEQUENCE
SEQUENCE LINE
1
SEQUENCE POINT
01
PRESET POSITION
001
SPEED
1
DWELL
TIME
001
RUN SEQUENCE
ENTER
EXIT
YES