Use and maintenance manual
Longitudinal profile welding
Model: LRWG-100
_______________________________________________________________________________________________________________________
P a g . 1 5
Do the same to remove the glue bottle.
Shut the welder down holding the wheel temperature of the Leister for 5 seconds and allowing it
to operate for about 5 minutes, to cool the heater element.
NOTE:
Not completing this cooling process, that is turning off the blower when the heater
element is still hot, could cause the heater element to fuse because of the increased
temperature inside the tube.
-
Care and maintenance
•
Because various chemical components are used during the welding process, there is an
accumulation of highly corrosive waste in the welding area (rollers, pulleys, guides, etc. and
so they should be cleaned regularly to ensure correct operation.
•
Do not grease or lubricate any component of the machine. These components are self-
lubricated, and the mixture of different lubricants could cause jamming or seizing.
•
Protect the pulleys from knocks that could mark or damage their profiles as they would
cause imperfections in the welding.
•
In the event of unusual noises in the welder, check the condition of the brushes. They have
relative wear.