Data of op to coup ler out put:
max. vol ta ge: 30 V
max. cur rent : 50 mA
Iso la ti on vol ta ge: 500 V
Tab le lo adre sis tors
max. output frequency
max. load resistor
25 kHz
1 kOhm
20 kHz
1 kOhm
15 kHz
1,5 kOhm
10 kHz
3 kOhm
5 kHz
6 kOhm
1 kHz
>6 kOhm
7.3.
Power Supply
8.
Startup Procedure
At ten ti on must be paid that po wer supply vol ta ge applied will agree with
t
he vol ta ge no ti ced at the name pla te.
When de li vered, the in tru ment is ad ju sted with a stan dard con fi gu ra ti on
(de fault va lue of the di vi der = 1). By chan ging the ad just ment the cu sto -
mer can al ter the stan dard con fi gu ra ti on ac cor ding to his mea su ring task.
At ten ti on !
When the in stru ment is built in a ma chi ne and the cu sto mer
wants to change the con fi gu ra ti on, at ten ti on must be paid, that no da ma -
ge will oc cur to the ma chi ne!
11
ERMA-Electronic GmbH
8. Startup Procedure
+
-