8.3.
Programming level for configuration P-00
Param.
Description
Setting range
Default
value
0-00
Resolution (Bits)
10 .. 25
12
0-01
Output code
0 ->
Gray
1 ->
Binary
0 .. 1
0
0-02
Master/Slave-Mode
0 ->
Instrument = Master
1 ->
Instrument = Slave
0 .. 1
0
0-03
Clock for Master-Mode
0 ->
Frequency = 200 kHz
1 ->
Frequency = 100 kHz
0 .. 1
0
0-04
Zero adjustment
0 ->
Zero adjustment without sign
1 ->
Zero adjustment with ± display
0 .. 1
0
0-05
Counting direction
0 ->
increasing clockwise rotation
1 ->
increasing anticlockwise rotation
0 .. 1
0
0-06
Scalingfactor
0.00001 .. 9.99999
1.00000
0-07
Offset value
-99999 .. 999999
0
0-08
Programmable decimal points
0 ->
XXXXXX
1 ->
XXXXX.X
2 ->
XXXX.XX
3 ->
XXX.XXX
4 ->
XX.XXXX
5 ->
X.XXXXX
0 .. 5
0
0-09
Data source of the display
0 ->
Encoder value
1 ->
MAX value
2 ->
MIN value
3 ->
Hold value
0 .. 3
0
0-10
Reset time of the MIN/MAX value
0 ->
No automatically reset
X ->
Reset time in seconds
0 .. 100
0
0-11
Function of digital user input 1
0 ->
No function
1 ->
Reset MIN/MAX value
2 ->
Taring of encoder
3 ->
Clear tara value of encoder
4 ->
Incremental measurement
0 .. 11
0
8. Procedure of programming
ERMA-Electronic GmbH
18
Содержание SSI 9001
Страница 38: ...13 Notices 13 Notices 37 ERMA Electronic GmbH ...
Страница 39: ......