2400TS SERIES
Erie Water Treatment Controls – Belgium
Page 2
Technical Specifications
Valve body material
Connections
- inlet/outlet (optional)
- drain line
- brine line
- tank
- riser tube
Mixing valve
Glass filled Noryl®
Brass adapters BSP, 3/4” male/female, 1” male
3/4” NPT with hose barb 13 mm
Compression fitting 3/8” polytube
2 1/2” - 8 NPSM
1,050” / 26,7 mm
Standard
Flow rates (valve with riser)
- service
- backwash
- fast rinse
Kv = 5,5 / Cv = 6,4
Kv = 1,7 / Cv = 2,0
Kv = 1,0 / Cv = 1,2
Application
Softener 7” - 16”
Operating pressure
Operating temperature
Electrical rating
1,4 - 8,3 bar / 20 - 120 psi
2 - 48 °C / 35 - 120 °F
24V - 50 Hz, max. 400 mA
Regeneration
Controller
- software
- regeneration initiation
- regeneration type
- time of regeneration
- regeneration interval
- backwash
- brine draw/slow rinse
- fast rinse/brine refill
4 cycles, co-current brining
Electronic with µ-processor and NOVRAM®
EAZY
Time clock or manual
Delayed
Adjustable
Adjustable: OFF, 1 - 30 days
Adjustable: 0 - 20 min
Adjustable: 0 - 120 min
Adjustable: 0 - 65 min
Содержание 2400TS Series
Страница 1: ... A Division of Aquion Inc 2400TS SERIES Technical Manual ...
Страница 15: ...2400TS SERIES Erie Water Treatment Controls Belgium Page 13 ...
Страница 21: ...2400TS SERIES Erie Water Treatment Controls Belgium Page 19 ...
Страница 26: ...2400TS SERIES Erie Water Treatment Controls Belgium Page 24 Exploded Views Part Numbers Electronic timer ...
Страница 28: ...2400TS SERIES Erie Water Treatment Controls Belgium Page 26 Valve body ...
Страница 31: ......