Control Network Redundancy
Overview
The control network is assigned to the physical Ethernet ports Ctrl1 and Ctrl2. The lower
number port of the pair is considered to be the
primary port
, and the other the spare.
Operation
If both ports have a link up, and the Control Port Selection is set to
Automatic
Redundant
, then the
primary port
will respond to network traffic, but the spare port will
not.
However, if the link goes down on the primary port, then the spare port will start to respond
to network traffic.
Automatic Redundancy Mode
In
automatic redundancy
mode the
primary port
is used as default. If the primary port
link fails, control passes to the secondary port. However, if the primary port link is restored
then control passes back to the primary after the
Auto-Revert
delay period.
The behavior of the system when the primary link is re-established depends on the Control
Port Auto-Revert Time setting.
If the Control Port Auto-Revert Time is set to 0, then the spare port remains the active
control port until its link goes down.
Otherwise, after the primary port has had a link present for the defined period of time, it will
resume being the active control port, and the spare port will cease responding to network
traffic.
© Ericsson AB 2011. All rights reserved
Содержание SPR1100
Страница 22: ......
Страница 23: ...Ethernet Port Numbering Ericsson AB 2011 All rights reserved ...
Страница 26: ......
Страница 27: ...Ethernet Port Numbering Ericsson AB 2011 All rights reserved ...
Страница 30: ......
Страница 31: ...Ethernet Port Numbering Ericsson AB 2011 All rights reserved ...
Страница 34: ......
Страница 35: ...Ethernet Port Numbering Ericsson AB 2011 All rights reserved ...
Страница 74: ... Ericsson AB 2011 All rights reserved ...
Страница 98: ... Ericsson AB 2011 All rights reserved ...
Страница 106: ... Ericsson AB 2011 All rights reserved ...
Страница 109: ... Ericsson AB 2011 All rights reserved ...
Страница 112: ... Ericsson AB 2011 All rights reserved ...
Страница 124: ... Ericsson AB 2011 All rights reserved ...
Страница 130: ...editable Ericsson AB 2011 All rights reserved ...
Страница 145: ... Ericsson AB 2011 All rights reserved ...
Страница 148: ......
Страница 161: ...alarms All traps i e start up events and all alarms and warnings Ericsson AB 2011 All rights reserved ...
Страница 170: ......
Страница 211: ... Ericsson AB 2011 All rights reserved ...
Страница 220: ... Ericsson AB 2011 All rights reserved ...
Страница 225: ... Ericsson AB 2011 All rights reserved ...
Страница 245: ...Home SPR1100 Handbook Appendices Alarm Lists Alarm Lists Base Unit MPM1 Ericsson AB 2011 All rights reserved ...