Supported Alteia Protocol Commands and Messages
2
Installing the Equipment
Warning!
Do not remove the covers of this equipment. Hazardous voltages are present within
this equipment and may be exposed if the covers are removed. Only Ericsson AB
trained and approved service engineers are permitted to service this equipment.
2.1
Hardware Interface
There is a single hardware port available on the back plane of the RX8200 IRD for the
Serial Remote Control, if the Remote Data (Legacy) Card is present. The port is
denoted with
RS232/RS485 Remote
.
Figure 1.
The backplane of the RX8200 including Remote Data Card
The serial communication mode can be
Half-Duplex
and
Full-Duplex
.
The Remote Control Port supports the
RS-232
and
RS-485
serial interfaces. The
electrical characteristics for the interface must be selected between RS-232 or RS-485
via one of the user interfaces.
(See User interfaces in Chapter 2.2)
RS-485 is intended for controlling multiple IRDs from a single controller. The Alteia
protocol includes addressing capabilities and will operate with both RS-232 and
RS-485.
Default configuration:
Remote address:
2
Remote interface:
RS-232
Remote duplexity:
Half duplex
8 (59)
Document No. ST.TS.EXXXXX.1 2010-03-04