Radio Terminals
Radio Frame
Multiplexer
Modulator
Cable
Interface
TDM
Multiplexer/
Demultiplexer
TDM
PCI
RCC
RAU A
Node
Processor
TA
Switch
TA
Switch
MMU A
NPU
Tx On/Off
(Hot Standby)
Tx On/Off
(Hot Standby)
Radio Frame
Multiplexer
Modulator
Cable
Interface
Control and
Supervision
TDM
Multiplexer/
Demultiplexer
RCC
RAU B
MMU B
TDM Tx
Switch
BPI
6666
Control and
Supervision
Figure 74
Tx Equipment Protection, Working and Hot Standby
4.6.2.2
Tx Equipment Protection Hot Standby
This protection case also involves the TDM Tx switch and the TA switch.
The difference from Tx Equipment Working Standby is that only one RAU is
active. Hence, Tx must be switched off in the malfunctioning Radio Terminal
and switched on in the standby. This is controlled by the DP in the Control and
Supervision block of the MMU and communicated in the RCC.
Alarms generated in the RAU and MMU are monitored by the NPU, which based
on the alarm severity commands the TDM and TA switches as appropriate.
The switching principles are illustrated in Figure 74 on page 95.
4.6.2.3
Radio Segment Protection
This protection case involves a Diversity switch in each MMU, providing hitless
and error free traffic switching in case of radio channel degradation. It is also
used as equipment protection in case of a signal failure in the RAU Rx parts.
95
12/221 02-CSH 109 32/1-V1 Uen A 2008-03-14
Содержание MINI-LINK TN R4 ETSI
Страница 1: ...Technical Description MINI LINK TN R4 ETSI MINI LINKTM ...
Страница 12: ...Technical Description 8 12 221 02 CSH 109 32 1 V1 Uen A 2008 03 14 ...
Страница 128: ...Technical Description 124 12 221 02 CSH 109 32 1 V1 Uen A 2008 03 14 ...
Страница 144: ...Technical Description 140 12 221 02 CSH 109 32 1 V1 Uen A 2008 03 14 ...