Technical Description
3.4.2.2
User In/Out
Six User In ports are available for connection of user alarms, such as fire or
burglar alarms, to be displayed in MINI-LINK management systems. The User
In ports can be configured to be normally open or normally closed.
Three User Out ports are available. The User Out ports are intended for
control of remote user’s functions and can be controlled by alarm severity or
an operator.
3.4.2.3
TDM
This block interfaces the TDM bus by receiving and transmitting the DCN
channels (1x64 kbit/s).
3.4.2.4
Control & Supervision
The block handles alarms and configuration.
3.4.2.5
SPI
This block interfaces the SPI bus and handles equipment status. Failure is
indicated by LED’s on the front of the unit.
3.4.2.6
Power
This block interfaces the Power bus and provides secondary voltages for the
unit. All plug-in units have a standard power module providing electronic soft
start and short circuit protection, filter function, low voltage protection, DC/DC
converter and a pre-charge function.
3.5
E1 Interfaces
This section describes the plug-in units providing short haul 120
balanced E1
(G.703) interfaces. In a mobile access network these are typically used for traffic
connection to a radio base station or for connection to leased line networks.
The MINI-LINK TN uses the same connectors for all E1 Interfaces.
3.5.1
NPU
NPU1 B provides eight E1 interfaces, NPU3 and NPU3 B provides four E1
interfaces, see Section 3.3.1 on page 18.
3.5.2
SXU
SXU3 B provides four E1 interfaces, see Section 3.6.3 on page 32.
26
12/221 02-CSH 109 32/1-V1 Uen A 2008-03-14
Содержание MINI-LINK TN R4 ETSI
Страница 1: ...Technical Description MINI LINK TN R4 ETSI MINI LINKTM ...
Страница 12: ...Technical Description 8 12 221 02 CSH 109 32 1 V1 Uen A 2008 03 14 ...
Страница 128: ...Technical Description 124 12 221 02 CSH 109 32 1 V1 Uen A 2008 03 14 ...
Страница 144: ...Technical Description 140 12 221 02 CSH 109 32 1 V1 Uen A 2008 03 14 ...