background image

IMPORTANT SAFETY INFORMATION

1.

SAVE THIS MANUAL It contains important safety
and operating instructions for Universal Desk Charger.

2.

Before using the battery charger, read all instructions and
cautionary markings on (1) the battery charger, (2) the
battery, and (3) the product using the battery.

3.

CAUTION  - To reduce the risk of injury, charge only
Ericsson battery packs using the proper battery sleeve.
Charging any other battery pack or batteries may cause
the battery to burst and cause personal injury or damage.

4.

Do not expose charger to rain or snow.

5.

Do not use auxiliary equipment not recommended or sold
by the manufacturer. To do so may result in a risk of fire,
electric shock, or injury to persons.

To reduce risk of damage to electric plug and cord, pull
by the plug rather than the cord when disconnecting the
charger.

7.

Make sure the cord is located so that it will not be stepped
on, tripped over, or otherwise subjected to damage or
stress.

8.

An extension cord should not be used unless absolutely
necessary. Use of an improper extension cord could result
in a risk of fire and electric shock. If an extension cord
must be used, make sure:

a. That pins on the plug of the extension cord are the

same number, size, and shape as those on the
charger’s plug;

b. That the extension cord is properly wired and in good

condition; and 

c. That the wire size is large enough for the AC ampere

rating of the charger as specified in Table 1.

9.

Do not operate charger with damaged cord or plug -
replace them immediately.

10. Do not operate charger if it has received a sharp blow,

been dropped, or otherwise damaged in any way; return it
to a qualified service shop.

11. Do not disassemble the charger; return it to a qualified

service shop when service or repair is required. Incorrect
reassembly may result in a risk of electrical shock or fire.

12. To reduce risk of electric shock, unplug the charger from

the outlet before attempting any maintenance or cleaning.

 13. GROUNDING AND AC POWER CORD CONNEC-

TION - To reduce the risk of electrical shock use only a
properly grounded outlet. The charger is equipped with an
electric cord having an equipment-grounding conductor
and a grounding plug. Be sure the outlet is properly
installed and grounded in accordance with all local codes
and ordinances.

14. DANGER - Never alter the AC cord or plug. If it will not

fit in the outlet, have a proper outlet installed by a qualified
electrician. Improper connection can result in risk of an
electric shock .

15. The Rapid Charger 120 Vac line cord has a grounding

plug that looks like the plug illustrated in Figure 1. A
temporary adapter, which looks like the adapter illustrated
in sketches B and C, may be used to connect this plug to
a two-pole receptacle as shown in sketch B if a properly
grounded outlet is not available. The temporary adapter
should be used only until a properly grounded outlet can
be installed by a qualified electrician.

16. DANGER  - Before using an adapter as illustrated, be

certain the center screw of the outlet plate is grounded.
The green- color rigid ear or lug extending from the
adapter must be connected to a properly grounded outlet-
-make certain it is grounded. If necessary, replace the
outlet cover plate screw with a longer screw that will
secure adapter ear or lug to outlet plate and make ground
connection to grounded outlet.

17.  Care should be taken when placing the charger in service

to insure proper top and bottom ventilation. A minimum
of 1/4" is required between the bottom of the charger and
the surface on which it sits. 

Figure 1 - Grounding Methods

Due to the temperature characteristics of nickel-cad-
mium batteries, the batteries will not accept a full
charge at temperature extremes. For maximum capac-
ity, recharge the battery pack at a room temperature of
65° to 85 ° Fahrenheit, whenever possible.

NOTE

AE/LZB 119 1643

3

Содержание BML 161 51/021

Страница 1: ...SERVICING TO QUALIFIED SERVICE PERSONNEL Maintenance Manual Universal Desk Charger Rapid BML 161 51 022 Standard BML 161 51 021 ericssonz CAUTION WARNING TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD DO NO...

Страница 2: ...ns of this manual No part of this manual may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying and recording for any purpose without the express...

Страница 3: ...rical shock or fire 12 To reduce risk of electric shock unplug the charger from the outlet before attempting any maintenance or cleaning 13 GROUNDING AND AC POWER CORD CONNEC TION To reduce the risk o...

Страница 4: ...Charger Not fused RECHARGE TIME Rapid Charger 1 hour Standard Charger 14 hours OPERATING TEMPERATURE RANGE 5 to 45 C DIMENSIONS HxWxD Height 4 4 inches 112 mm Width 4 7 inches 118 5 mm front 5 3 inch...

Страница 5: ...ck in 14 hours The charge current for the charger is provided by the wallcube step down transformer Aseries resistor selected by the long or short battery pack microswitch controls the amount of charg...

Страница 6: ...43 Charger Sleeve M PA M PD MTL PLS TPX BML 161 51 001 PCS BML 161 51 002 M RK BML 161 51 003 MONOGRAM TRUNKING BML 161 51 004 PRISM HP BML 161 51 005 Standard Charger Board F29 4R A9 0086 Rapid Charg...

Страница 7: ...ng an acceptable rapid charge This condition may result if the battery is too hot or cold weak or dead or defective If the blinking CHARGE indicator does not turn to a continuous RED after 15 minutes...

Страница 8: ...Remove A Battery Pack Simply reach into the cutouts provided in the sides of the charging insert and lift the battery pack out DEFINITIONS Dead Battery Battery pack with low voltage due to long term...

Страница 9: ...n 1 Remove the charger sleeve 2 Removefourcasescrews items 14 17 Gentlyseparate the bottom assembly item l from the body item 2 3 Disconnect the LED cable item 8 from connector CNI on the charger boar...

Страница 10: ...e Power Supply perform the following steps 1 Disassemble the charger see Case disassembly proce dure 2 Remove the Charger Control Board see Charger Control Board removal 3 Remove the two screws item 3...

Страница 11: ...c 0 5 Vdc at CN2 pin 1 If the output voltage is out of range the power supply assembly is defective and must be replaced 2 With a known good battery as a load check the output yoltage of the Charge Co...

Страница 12: ...laced with a known good battery If normal operation results the batteryis defective If theproblempersists the voltage detection of the PCB has failed which requires replace ment of the Charge Control...

Страница 13: ...d on the Standard Charger Board This board receives low voltage AC from the wall cube trans former This AC supply is converted to DC by a full wave bridge rectifier consisting of DI D2 D3 and D4 The c...

Страница 14: ...STANDARD CHARGER BML 161 51 021 CHARGER BOARD F29 4R A9 0086 3R M5 0028 SCHEMATIC DIAGRAM AE LZB 119 1643 14...

Страница 15: ...SCHEMATIC DIAGRAM RAPID CHARGER BML 161 51 022 POWER SUPPLY BOARD part of F29 4R A9 0082 3R M5 0017 AE LZB 119 1643 15...

Страница 16: ...RAPID CHARGER BML 161 51 022 CONTROL BOARD F29 4R A9 0083 2R M5 0018A SCHEMATIC DIAGRAM AE LZB 119 1643 16...

Страница 17: ...PARTS LIST AE LZB 119 1643 17...

Страница 18: ...STANDARD CHARGER BML 161 51 021 3R K5 0016 ILLUSTRATED PARTS BREAKDOWN AE LZB 119 1643 18...

Страница 19: ...RAPID CHARGER BML 161 51 022 2R K5 0015 ILLUSTRATED PARTS BREAKDOWN AE LZB 119 1643 19...

Страница 20: ...Ericsson Inc Private Radio systems Mountain View Road Lynchburg Virginia 24502 AE LZB 119 1643 R1A 1 800 528 7711 Outside USA 804 528 7711 Printed in U S A AE LZB 119 1643...