LED detailed description
Table 3, LED symbols
Symbol
Name
LED Color
Fault LED
Red
Operational LED
Green
Maintenance LED
Blue
Fault
LED
have two states:
1. Major fault: Slow flashing ~0.5 Hz.
2. No fault: Steady OFF.
Operation
LED
:
1. Power off: Steady OFF
2. Normal operation: Steady ON
3. Software loading: Double flashing, followed by a longer steady state
LED indication of the current operational state (i.e. for the steady state
the LED can be either ON or OFF reflecting the actual state)
4. No network connection (no IP Backhaul): Slow flashing 0.5 Hz
Maintenance
LED
:
1. Power off: Steady OFF
2. On or flashing: Maintenance needed.
7.5
Performance management
The purpose of Performance Management is to gather information about
Gateway 5780 hardware performance, backhaul and to provide Performance
Measurements for LoRaWAN
™ network performance. The Performance data
sent upstream to network performance monitoring system.
7.6
Hardware management
The Gateway 5780 is a single hardware unit and is also the replaceable part.