Programmable Presets
Program your preferred height and tilt positions right into the table! Carl's Table CT15 has 100 programmable presets. The preset
display indicates which setting is active.
To preset a table position:
1) Move the table to the desired height and tilt position.
2) Enter the two-digit number you want to record.
3) Press and hold down the "SET" button for 5 seconds. The display number will fl ash until the table has recorded the setting.
To position the table to your preset:
1) Enter your two-digit number on the keypad.
2) Press and hold the "GO" button until the table reaches the stored position. The table will stop moving if you stop pressing
the "GO" button.
NOTE: If the red light on the Comfort Control interface is illuminated, the table will not move because one of the safety switches
has been triggered. Read "Troubleshooting" (page 6) or "Some Safety Considerations" below for more information.
Some Safety Considerations
Carl’s Table has a collision avoidance system and will stop the table from moving if it encounters an obstacle while tilting or
moving downwards. Safety sensors are located under the CPU Holder, under the control box, and under the work surface. If a
sensor is triggered, the table will stop moving and the red light on the Comfort Control interface will illuminate.
To avoid injury, stay clear of moving parts while the table is in motion. Do not sit on top of the workstation.
Electrical Requirements
Facilities electrical requirements: dedicated 15 or 20Amp circuit, 120Vac, NEMA 5-15R receptacle.
Power Draw
Power draw: Parasitic
Conditions:
• Lights
off
•
No computer equipment con-
nected
to the table
•
No table movement
Power draw:
•
Amps: 179mA
•
Watts: 8.835
•
VA: 21.73
•
PF: .407
Power draw: Idle
Conditions:
•
All lights on full brightness
•
Both fans on
•
No computer equipment
connected to the table
•
No table movement
Power draw:
•
Amps: 464.2mA
•
Watts: 47.54
•
VA: 56.29
•
PF: .844
Power draw: Worst case
Conditions:
•
All lights on full brightness
•
Both fans on
•
No computer equipment con-
nected
to the table
•
Worst case with table and tilt mov-
ing
Power draw:
•
Amps: 3.01
•
Watts: 292.90
•
VA: 361.1
•
PF: .811
300-5642-00 rev. C