Operating Instruction
Spindle lifting system SLA/SLG VD
Document no.: B-00081
Edition 2019 02
Operating instruction EN
Copyright by Ergoswiss AG
5/20
1.4
Performance characteristics
1.4.1
Linear unit SLA 13xx
Max. allowed pressure load
1'500 N
Max. allowed tensile load
1'500 N
Max. stat. bending moment
150 Nm
Max. dyn. Bending moment
50 Nm
1.4.2
Linear unit SLG 13xx
Max. allowed pressure load
1'500 N
Max. allowed tensile load
1'500 N
Max. stat. bending moment
200 Nm
Max. dyn. Bending moment
80 Nm
1.4.3
Motor SX D30 24 V
Nominal voltage
24 V
Nominal torque
2.5 Nm
Idle speed
352 min
-1
Nominal power
64 W
Nominal current
5.55 A (no-load current 0.33 A)
1.4.4
Control box VD SCT2 and SCT4
Supply voltage
EU: 207 - 254.4 V / 50 Hz
US: 90 – 127 V / 50-60 Hz
Primary standby power
< 0.5 W
Power
280 VA (SCT2) ; 340 VA (SCT4)
Ambient temperature
0 – 40 °C
Humidity
5 – 85 % (not condensating)
Protection class (DIN EN 60529)
IP 20
Performance level (DIN EN 13849-1)
PL b
Dimensions (L, B, H)
260 x 120 x 50 mm
1.4.5
Manual control switch VD Up / Down and memory
Kable length
2'000 mm
Ambient temperature
0 – 40 °C
Protection class (DIN EN 60529)
IP 30