![Ergoswiss 901.41017 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/ergoswiss/901-41017/901-41017_operating-instruction_2422429006.webp)
Operating Instruction
Spindle lifting system SL/SM 13xx with SCT iSMPS
Document no : B-00361
Edition 2020 06
Operating instruction EN
Copyright by Ergoswiss AG
6/27
2.2
Intended purpose use
Field of application
NO field of application
•
Height adjustment of work surfaces
•
Height adjustment of machine parts
•
Height adjustment of profile systems
•
… List not final
•
Clamping device
•
Press (or counter stop for press)
•
Passenger transport
•
Security component
•
… List not
final
The lifting system can be used if:
•
it is located at enclosed spaces, dry and non-explosive environments.
•
ambient temperature is b10 °C and +40 °C.
•
relative humidity range is between 30 % and 70 % (not condensed).
•
there are no strong electromagnetic fields nearby.
The lifting system must not be:
•
operated outside the performance data (tensile, pressure, bending torque)
•
loaded with pulse or impact forces (e.g. displacing loads).
•
designed for continuous operation (the duty cycle (On/Off) must not exceed 2/40).
•
operated with inadmissible or unintended components
(e.g. different types of lifting column; Replacement of the controller (control software))
•
operated with damaged components
•
open or post-processed
•
used by children under 8 years of age or persons with limited physical, sensory or mental abilities.
Unless they are supervised by a person responsible for their security or receive instructions by this
very person on how to use the device.
When installing and operating the lifting system, the intended purpose of the entire system must be adhered
to. Commissioning is prohibited until the entire plant complies with the provisions of EG Machinery Directives
2006/42/EG (Machinery Directive). For this purpose, it is essential to perform a risk analysis, so that possible
residual hazards can be reacted to (e.g. by constructive measures or by means of instructions in the operat-
ing instructions or/and by safety instructions on the system). In the event of improper use, the liability of
Ergoswiss AG as well as the general operating licence of the lifting system expires.
2.3
Target group and prior knowledge
Before installing and operating the lifting system, this operation instruction must be read and understood.
The user manual must be kept in the immediate vicinity of the system for a look-up.
This manual is intended for the following groups of people:
The
manufacturer of the complete system
, who integrates this lifting system into a complete system
and integrates this operating manual into the operating instructions of the entire system.
The
commissioning personnel
, who install the lifting system in a workstation, a machine, etc. and put it
into operation. Basic mechanical and electrotechnical knowledge is required during commissioning.