Operating instruction
Spindle lifting system SL/SK/SM 14xx Compact
Document no.: B-00061
Edition 2022 05
Operating instruction EN
Copyright by Ergoswiss AG
Page
22
of
26
8
Safety strip – Squeezing protection
ATTENTION
With lifting systems of Ergoswiss AG it is important to make sure that no objects or people are
trapped during the lifting movement.
Danger of squeezing during lifting movement!
Attach the safety strip to an assumed squeeze zone. If the safety strip gets squeezed while the system
moves, the motor will stop instantly and turn back for one motor rotation (4 mm
(0.16’’))
.
The Safety strip Compact cpl. (124.00105) consists of:
Functional properties of the contact tube
Contact angle
< 80 °
Switching pressure
< 25 N bei 23 °C
Switching travel
< 2 mm bei 23 °C
Minimum bending radius
B
1
120 mm / B
2
150 mm
B
3
20 mm / B
4
20 mm
Max. tensile load
20 N
Electrical properties
Terminal resistance
2.2 k
Ω
hm
Max. switching capacity
250 mW
Max. voltage
DC 24 V
Current min. / max.
1 mA / 10 mA
8.1
Commissioning
Gluing the contact tube in the squeeze zone
1.
Clean and degrease the contact face
2.
Remove 10-15 cm
(4’’ to 6’’)
of protective film from the adhesive surface
3.
Place it on the contact face and press on well
4.
Repeat steps 2 and 3 until the contact tube is completely glued on
5.
Maximum adhesion is reached after 24 h
Initial operation of control box with the safety
strip
Adding the safety strip to existing control box
1.
Wire the control box according to chapter 3.2.
The safety strip is connected in step 2.b
2.
Perform an initial operation according to chapter 4.
1.
Reset the controller to factory setting
(see chapter 5.5). The safety strip is connected in
step 2.b.
Adaptor cable for
Connection cable for
Contact hose
Endpiece with
Safety strip Compact
Safety strip Compact (RJ-45)
for Safety strip
resistance 2.2kΩ
124.00106
124.00107
124.00101
124.00118
10 mm
185 mm
(7.3’’)
2'500 mm
(98.4’’)
variable (100-5'000 mm)
(4’’-197’’) (0.4’’)