Operating instruction
Spindle lifting system SL/SK/SM 14xx Compact
Document no.: B-00061
Edition 2022 05
Operating instruction EN
Copyright by Ergoswiss AG
Page
18
of
26
5.5
Chaning the display unit of measurement (mm/inch) – Reset «S 5»
NOTE
No lifting movement is allowed during the reset.
1.
Press the buttons
1
,
2
and
simultaneously, until «S 5» or «S 7» is displayed.
The control box is now in setting mode.
2.
Press the button
until
«S 5»
is displayed.
3.
Press the button
S
(Save).
Control box clicks 2 times …
The unit of measurement on the display has now been changed from millimeters (mm) to inches (inch) or
from inches to millimeters (25.4 mm = 1 inch).
NOTE
If the unit of measurement should be changed again, repeat steps 1-3.
5.6
Restore to factory settings – Factory reset «S 0»
ATTENTION
Before restoring to factory settings, it must be ensured that:
- the lifting element can retract completely.
- the lifting system is loaded with a maximum of 50% of the maximum allowed system load.
If the lifting element cannot retract completely and hits a stop before it reached its lower
block position, the zero position is set incorrectly. This leads to a collision when moving up to
the upper block position.
NOTE
During restoring to the factory settings, the lifting system drives with half the speed.
When restoring the factory settings, the entire system is newly set up again.
All settings such as Memory positions or End positions are lost.
1.
If possible: Drive to lowest position
This saves time because the system only drives with half speed when doing a reset.
2.
Press the buttons
1
,
2
and
simultaneously, until «S 5» or «S 7» is displayed.
The control box is now in setting mode.
3.
Press the button
until
«S 0»
is displayed.
4.
Press the button
S
(Save).
The display is blinking «068» (US – 110 V version «027»)