Press „Operating mode“ (1) button.
•
Unused displays disappear.
•
The currently set operating mode flashes for 5 seconds.
•
+ and – appear.
Press (2) or – (3) until the required operating mode is displayed.
7.7 Setting mode of operation at the sealing
head
Fig. 28
3
2
1
•
MAN = Manual
The tensioning button must be pulled and held until the desired strap
tension has been reached. The welding button must then be briefly
pressed so that the straps are welded and the upper strap is cut off.
•
SEMI = Semi-automatic strapping (standard/factory setting)
The tensioning button must be pulled and held until the set tension force
has been reached. The straps are then automatically welded and the
upper strap is cut off. It can be welded manually at any time by pressing
the welding button.
-31-
MAN/ SEMI/ AUTO
By pressing the „Operating mode“ button (1) again, or after waiting 5 seconds,
the set mode is saved. Each operating mode can also be selected for the
tension range „Soft tension“ (Section 7.5).