Super Shot 125 DC 70CFM EU Part Manual
Chapter 8 Troubleshooting
©2022 by Crafco, Inc. All Rights Reserved
………………………………………………………...Troubleshooting (48300N) 8-1
8.0 Troubleshooting
8.1 Diesel Burner Troubleshooting
Symptoms: Burner will Not Ignite
Step
Possible Cause
If . . .
1
Start Troubleshooting at the control box. Is
the diesel engine running?
•
Yes, go to Step 2.
•
No, start the diesel engine.
•
Note
:
You can troubleshoot the burner
without the engine running, but you must
connect a battery charger to the battery and
the ignition must be in the “ON” position.
2
Is the “MAIN POWER” toggle switch in the
“ON” position?
•
Yes, go to Step 3.
•
No, turn the toggle
switch to the “ON”
position.
3
Is the “BURNER” toggle switch in the “ON”
position?
•
Yes, go to Step 4.
•
No, turn the toggle
switch to the “ON”
position.
4
Are both the Material and Hot Oil
temperature dials set to proper operating
temperatures?
•
Yes, go to Step 5.
•
No, set the Material according to the type of
sealant you are using and the Hot Oil 100°F
above the Material set point.
5
Are both the Material and Hot Oil
temperature displays reading a three-digit
positive number?
•
Yes, go to Step 6.
, Step 6.
6
Is the red "Burner" light "ON"?
•
Yes, go to Step 7.
•
, Step 4.
7
Is the diesel tank full?
•
Yes, go to Step 8.
•
No, fill your tank or make sure you have
enough fuel for the day.
Table 8-1 Basic Visual Troubleshooting
Содержание Crafco SUPER SHOT 125
Страница 1: ...Parts Manual 26635N Revision E SUPER SHOT 125 DIESEL COMPRESSOR 70CFM EU MELTER...
Страница 4: ...Super Shot 125 Diesel Compressor 70 CFM EU Melter PN 48300N...
Страница 5: ......
Страница 16: ......
Страница 26: ......
Страница 42: ......
Страница 72: ......
Страница 76: ......
Страница 120: ......
Страница 170: ......
Страница 174: ......
Страница 175: ......
Страница 176: ...2022 Crafco Inc...