Cleaning and maintenance
40/58
4.7.3
Open the bed base
–
Raise the acrylic glass panel and grasp the recessed grip.
–
Lift up the bed base.
The assembly is the same process in reverse order.
4.8
Instructions for replacing the lamps
DANGER!
Danger of burns from hot lamps and surfaces!
Finger and hands may get burned when replacing lamps.
–
Before carrying out maintenance work, wait until the
device has cooled down sufficiently.
UV filters are utilized in order to control the UV radiation, e.g. the filter panels
on the facial tanner. However, the filter effect decreases over the course of
time. Therefore, the intervals specified in the maintenance plan must be ad-
hered to.
NOTICE:
Small quantities of mercury can escape if the bulb/lamp
glass breaks!
Please comply with the following instructions:
Immediately disconnect the device from the mains pow-
er.
Children must leave the room immediately.
Ventilate the room for at least 15 minutes.
Put on disposable gloves.
With the window open: Collect the glass shards and
escaped mercury in a sealable container.
Bring the container to a collection site for waste lamps.