Maintenance
25
1
2
3
4
5
6
7
8
9
10
11
4.3 Disconnecting the sunbed from the
mains/preventing from switching on
4.3.1 Disconnecting from mains
01605 / 1
Danger!
•
=
Whenever you need to do work on the sunbed,
you must first disconnect it. This means that all
electrical wires must be switched off.
•
=
Switching off the sunbed alone is not sufficient as
certain parts of the equipment may still be live.
You must therefore switch off all fuses and
remove them if possible.
4.3.2 Preventing from switching on again
Danger!
Accidental switching on again of the sunbed can cause
very serious accidents.
As soon as the sunbed has been disconnected, you
must secure all disconnected switches and fuses
against being accidentally switched on again.
•
=
Secure the fuse box with a padlock
•
=
On automatic cut-outs that cannot be removed, a
length of adhesive tape bearing the words ”Do
not switch on – DANGER” can be stuck over the
switches (1) and (2).
01511 / 0
A prohibition sign with the words
•
=
”Work in progress!”
•
=
”Location”
•
=
”This sign may only be removed by:....”
must be displayed securely at all times.
Danger!
Prohibition signs must not be attached to or make
contact with parts that are live.
Содержание Classik 475
Страница 2: ...Ergoline Pro Sunbed from the No 1 2 ...
Страница 8: ...8 ...
Страница 14: ...General 14 1 2 3 4 5 6 7 8 9 10 11 ...
Страница 36: ...Maintenance 36 1 2 3 4 5 6 7 8 9 10 11 ...
Страница 40: ...Fault cause and remedy 40 1 2 3 4 5 6 7 8 9 10 11 ...
Страница 44: ...Technical data 44 1 2 3 4 5 6 7 8 9 10 11 ...
Страница 46: ...After sales service 46 1 2 3 4 5 6 7 8 9 10 11 ...
Страница 50: ...Warranty EU Conformity 50 1 2 3 4 5 6 7 8 9 10 11 ...
Страница 53: ......