Содержание Hera II Maxi/250

Страница 1: ...portant information This Manual must be read before the product is used This manual is intended for technicians installers therapists and other personnel in connection with the use servicing and maint...

Страница 2: ...2...

Страница 3: ...packing 6 1 6 Transport 6 2 Assembly instruction 7 3 Use and adjustment 3 1 Using the Hera II 7 3 2 Using the tilt function 7 3 3 Adjusting the Hera II 8 4 Maintenance 4 1 Cleaning 9 4 2 Storage 9 5 C...

Страница 4: ...iminated Hera II is intended for indoor use under normal temperatures 20 40 C and relative humidity 40 90 1 2 Safety instructions This user instruction must be read thoroughly before the Hera II is ta...

Страница 5: ...arer is responsible for ensuring that a daily check is carried out BEFORE Hera II is used including the following 1 Ensure that there are no parts missing 2 Check that there are no signs of rust wear...

Страница 6: ...product is to be used on other sites or for return shipment in case of repair 1 6 Transport The Hera II is most safely transported using the original packing Symbols are printed on the packaging to en...

Страница 7: ...he Hera II The Hera II chair is normally used in the following situations 1 When washing in the bathroom under the shower or by the bath 2 When transporting the user to the bathroom 3 For other purpos...

Страница 8: ...automatically angle itself according to the pressure of the user It can also be moved up or down to suit individual needs 1 Loosen the screws on the brackets placing the unit at the correct height an...

Страница 9: ...ironment with relative humidity under 90 5 Check The chair must be serviced and thoroughly checked at least twice a year by qualified and authorised personnel It is the onus of the buyer to ensure tha...

Страница 10: ...d in an environmentally correct way either through reuse or recycling 7 2 Quality Ergolet is certified according to the quality standard ISO 9001 and ISO 13485 These certifications mean that the produ...

Страница 11: ...forward backrest Hera II Maxi Seat lid 047 00250 047 00255 047 00260 047 00261 047 00550 PU seat Seat with hygiene opening Lid for PU seat Lid for hygiene opening Gel cushion Foot leg support 047 0003...

Страница 12: ...12 Phone 45 70 27 37 20 Fax 45 70 27 37 19 Email ergolet ergolet dk www ergolet com Manufacturer Ergolet Taarnborgvej 12 C 4220 Korsoer Denmark 9 3 4 2 E F C L A S S I E N I S O 1 0 5 3 5 910 00765UK...