EG_GenLoc41e_1055_UG_003_UK
Page 41 / 71
Descriptions and non-contractual illustrations in this document are given as an indication only.
ERCOGENER reserves the right to make any modifications.
Dct_427_02
7.3.4 3.8V
The tension available on the pin 13 of the 15-pin sub D HD is: see table below
Table: Conditions of use
Parameters
Condition
Min.
Typ.
Max.
Unit
V
out
6
.5 V ≤ +V
DC
≤ 32V
3.8
Vdc
I
out
Max.
100
mA
When the battery option is present, the tension available on the pin 13 of the 15-pin sub D HD
is
Parameters
Condition
Min.
Typ.
Max.
Unit
V
out
Without power supply * 2.8
4.2
Vdc
7.2
V ≤ +V
DC
≤ 32V
4.4
4.5
Vdc
I
out
Max.
100
mA
* The min. 2.8 V is the limit of auto protection of the battery. From this moment, the battery
puts itself in protection, and the output voltage becomes null.
When the battery is not connected, the output voltage is de
4.4V ≤ Vout ≤ 4.5 V as long as
the power V
DC
is present