250W MULTI CUTTER
ERB620HTL
NOTE
:
Not all above list accessory is included, the
including accessory please refer accessory list, if
you use others accessories please buy well know
brand accessories.
NOTE:
When plunging and sawing use a slight
pendulum motion, to allow sufficient chip removal.
The saw blade lasts longer if the wear is distributed
evenly. To ensure an even distribution, loosen the
saw blade, rotate it and retighten firmly.
Cut/Sand with a constant movement and light
pressure.
Heavy pressure does not increase the cut/removal
rate – the accessory merely wears faster.
Excessive use and heat build up drastically reduces
the life of saw blades.
WORKING HINTS FOR YOUR TOOL
If your power tool becomes too hot, especially when
used at low speed, set the speed to maximum and
run it with no load for 2-3 minutes to cool the motor.
Avoid prolonged usage at very low speeds. Always
keep the blade sharp.
Always ensure the workpiece is firmly held or
clamped to prevent movement.
Any movement of the material may affect the quality
of the cutting or sanding finish.
Start your tool before working and turn it off only
after you stop working.
Do not start sanding without having the sandpaper
fitted.
Do not allow the sandpaper to wear away , it will
damage the sanding pad. The guarantee does not
cover sanding pad wear and tear.
Use coarse grit paper to sand rough surfaces,
medium grit for smooth surfaces and fine grit for
finishing surfaces. If necessary, first make a test run
on scrap material.
Excessive force will reduce the working efficiency
and cause motor overload. Replacing the accessory
regularly will maintain optimum working efficiency.
MAINTENANCE
Remove the plug from the socket before
carrying out any adjustment, servicing or
maintenance.
Your power tool requires no additional lubrication or
maintenance. There are no user serviceable parts
in your power tool. Never use water or chemical
cleaners to clean your power tool. Wipe clean with
a dry cloth. Always store your power tool in a dry
place. Keep the motor ventilation slots clean. Keep
all working controls free of dust. Occasionally you
may see sparks through the ventilation slots. This is
normal and will not damage your power tool.
If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.