GENERAL SAFETY INSTRUCTIONS

WARNING! Read all safety warnings and all instructions.

 Failure to follow the 

warnings and instructions may result in electric shock, fire and/or serious injury.

Save all warnings and instructions for future reference

.

The  term  “power  tool”  in  the  warnings  refers  to  your  mains-operated  (corded)  power  tool  or 

battery-operated (cordless) power tool.
        

1.  Work area safety

a. Keep work area clean and well lit.

 Cluttered or dark areas invite accidents.

b. Do not operate power tools in explosive atmospheres, such as in the presence 

of flammable liquids, gases or dust. 

Power tools create sparks which may ignite the 

dust or fumes.

c. Keep children and bystanders away while operating a power tool.

 Distractions 

can cause you to lose control.

2.  Electrical safety

a. Power tool plugs must match the outlet. Never modify the plug in any way. Do 

not use any adapter plugs with earthed (grounded) power tools.

 Unmodified plugs 

and matching outlets will reduce risk of electric shock.

b. Avoid body contact with earthed or grounded surfaces, such as pipes, 

radiators, ranges and refrigerators. 

There is an increased risk of electric shock if your 

body is earthed or grounded.

c. Do not expose power tools to rain or wet conditions.

 Water entering a power tool 

will increase the risk of electric shock.

d. Do not abuse the cord. Never use the cord for carrying, pulling or unplugging 

the power tool. Keep cord away from heat, oil, sharp edges or moving parts. 

Damaged or entangled cords increase the risk of electric shock.

e. When operating a power tool outdoors, use an extension cord suitable for 

outdoor use. 

Use of a cord suitable for outdoor use reduces the risk of electric shock. 

f. If operating a power tool in a damp location is unavoidable, use a residual current 

device (RCD) protected supply.

 Use of an RCD reduces the risk of electric shock.

3.  Personal safety

a. Stay alert, watch what you are doing and use common sense when operating 

a power tool. Do not use a power tool while you are tired or under the influence 

of drugs, alcohol or medication. 

A moment of inattention while operating power tools 

may result in serious personal injury. 

b. Use personal protective equipment. Always wear eye protection. 

Protective 

equipment such as dust mask, non-skid safety shoes, hard hat, or hearing protection 

used for appropriate conditions will reduce personal injuries. 

c. Prevent unintentional starting. Ensure the switch is in the off-position before 

connecting to power source and/or battery pack, picking up or carrying the tool. 

Carrying power tools with your finger on the switch or energising power tools that have 

the switch on invites accidents. 

d. Remove any adjusting key or wrench before turning the power tool on. 

A wrench or a key left attached to a rotating part of the power tool may result in personal injury. 

e. Do not overreach. Keep proper footing and balance at all times. 

This enables 

better control of the power tool in unexpected situations. 

Содержание ERB385DRL

Страница 1: ...900W PERCUSSION DRILL ERB385DRL...

Страница 2: ...Original Instructions Version 1 0...

Страница 3: ...the goods This guarantee does not affect your statutory rights This guarantee is only valid in the UK For further technical advice spare parts or repair service outside of guarantee please contact the...

Страница 4: ...ging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock e When operating a power tool outdoors use an extension cord...

Страница 5: ...ore idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untr...

Страница 6: ...n 8 Ensure your supply voltage is the same as your tool rating plate voltage 9 Your tool is double insulated for additional protection against a possible electrical insulation failure within the tool...

Страница 7: ...one tool with another tool The declared vibration emission value may also be used in a preliminary assessment of exposure Warning The vibration emission value during actual use of the power tool can d...

Страница 8: ...p identity any vibration related diseases at an early stage prevent disease progression and help employees stay in work Double insulation The tool is double insulated This means that all the external...

Страница 9: ...al products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice RyyWxx Manufacturing date code Year of...

Страница 10: ...1 3 5 4 2 6 7 8 9...

Страница 11: ...0W PERCUSSION DRILL 1 KEYED CHUCK 2 AUXILIARY HANDLE 3 GEAR BOX SWITCH 4 FORWARD AND REVERSE ROTATION CONTROL 5 ON OFF SWITCH 6 SWITCH LOCK ON BUTTON 7 DEPTH STOP 8 HAMMER OR DRILL SELECTOR 9 CHUCK KE...

Страница 12: ...lass II Chuck capacity max 13mm Drilling capacity max Steel 13mm Masonry 20mm Wood 40mm Machine weight 2 7kg NOISE AND VIBRATION DATA A weighted sound pressure LpA 95dB A A weighted sound power LwA 10...

Страница 13: ...emove screws or release a jammed drill bit See Fig 2 Never change the direction of rotation when the tool is rotating wait until it has stopped 4 AUXILIARY HANDLE Slide the handle onto the drill and r...

Страница 14: ...be used for concrete and masonry When drilling in metal only use HSS drill bits in good condition Always use a magnetic bit holder when using short screwdriver bits Where possible use a pilot hole bef...

Страница 15: ...OTECTION Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice For further inf...

Страница 16: ...which is colored blue must be connected to the terminal which is marked with N The wire which is colored brown must be connected to the terminal which is marked with L Warning Never connect live or n...

Страница 17: ...004 108 EC EC Low Voltage Directive 2006 95 EC Restrictions of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment 2002 95 EC Waste Electrical and Electronic Equipment WEEE...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: