Erbauer ERB2151SE Скачать руководство пользователя страница 6

6

ERBAUER 216MM (8”) SLIDING MITRE SAW

ADDITIONAL SAFETY INSTRUCTIONS FOR YOUR MITRE SAW

ADDITIONAL SAFETY INSTRUCTIONS FOR YOUR MITRE SAW

             

                 

Warning: Be sure to read and understand all instructions. Failure to 

         follow all instructions listed below may result in electric shock, fi re 
and/or serious personal injury.
1.    Know your power tool. Read operator’s manual carefully. Learn the 

applications and limitations, as well as the specifi c potential hazards 
related to this tool.

2.    Always wear safety glasses or eye shields when using this mitre saw. 

Everyday eyeglasses have only impact-resistant lenses; they are not 
safety glasses.

3.    Always protect your lungs. Wear a face mask or dust mask if the 

operation is dusty.

4.    Always protect your hearing. Wear hearing protection during extended 

periods of operation.

5.    Always inspect the tool cords periodically and if damaged have them 

repaired. Always be aware of the cord location.

6.    Always check for damaged parts. Before further use of the tool, 

aguard or other part that is damaged should be carefully checked to 
determine if it will operate properly and perform its intended function. 
Check for misalignment or binding of moving parts, breakage of parts, 
and any other condition that may affect the tool’s operation. A guard 
or other part that is damaged, should be properly repaired or replaced 
at an qualifi ed service centre.

7.    Do not abuse the cord. Never use the cord to carry the tools or pull 

the plug from the outlet. Keep cord away from heat, oil, sharp edges 
or moving parts. Replace damaged cords immediately. 

Damaged cords 

increase the risk of electric shock.

8.    Always make sure that your extension cord is in good condition. When 

using an extension cord be sure to use one that is heavy enough to 
carry the current that your tool will draw.

 

9.    Always inspect and remove all nails from lumber before sawing.
10. Do not use the tool while tired or under the infl uence of drugs, alcohol 

or any medication. 

Following this rule will reduce the risk of electric shock, fi re or 

serious personal injury.

11. Save these instructions. Refer to them frequently and use them to 

instruct others who may use this tool. If someone borrows this tool, 
make sure they have these instructions also.

        

Содержание ERB2151SE

Страница 1: ...1 ERBAUER 216MM 8 SLIDING MITRE SAW 2 2WARRANTY WARRANTY YEARS YEARS ERB2151SE...

Страница 2: ...2 ERBAUER 216MM 8 SLIDING MITRE SAW...

Страница 3: ...within the rst 24 months you may return the goods for a full refund or we will repair or replace the goods if you prefer When repair is not practical or identical goods are not available alternative g...

Страница 4: ...abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric s...

Страница 5: ...Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the power tools operation If damaged have the power tool repaired before use Many accidents...

Страница 6: ...is damaged should be carefully checked to determine if it will operate properly and perform its intended function Check for misalignment or binding of moving parts breakage of parts and any other con...

Страница 7: ...lighting of the immediate work area 22 When tted with laser no exchange with different type of laser is permitted Repairs shall only be carried out by the laser manfacturer or an authorised agent 23 R...

Страница 8: ...n the electrical and mechanical components making it unnecessary for the tool to be earthed Important note Be sure the supply is the same as the voltage given on the rating plate The tool is tted with...

Страница 9: ...ADE 6 6 TABLE INSERT TABLE INSERT 7 7 MITRE HANDLE MITRE HANDLE 8 8 LASER GUIDE LASER GUIDE 9 9 BASE BASE 10 10 TURNTABLE TURNTABLE 11 11 LEFT EXTENSION TABLE LEFT EXTENSION TABLE 12 12 FENCE FENCE 13...

Страница 10: ...AGE 17 17 BEVEL LOCK HANDLE BEVEL LOCK HANDLE 18 18 RIGHT EXTENSION TABLE RIGHT EXTENSION TABLE 19 19 MOTOR MOTOR 20 20 POSITIVE STOP LOCKING LEVER POSITIVE STOP LOCKING LEVER 21 21 LOWER BLADE GUARD...

Страница 11: ...0W S6 20 10min No load speed 4800min 1 Double insulation Net weight 14 2 kg Blade 216 mm 30 mm Bore Turntable 230 mm Mitre stops 0 15 22 5 31 6 45 left right Mitre angle range 45 left right Bevel angl...

Страница 12: ...on of loss there is a slot 1 located at the rear of cutting handle for storing the blade spanner 2 See Fig 5 4 Cutting head Raising 1 Push down slightly on the switch handle 4 and the lock lever 5 2 P...

Страница 13: ...ry Always unplug the saw to avoid accidental starting Remove all small pieces of material from the table cavity before performing any cuts The table insert may be removed for this purpose but always r...

Страница 14: ...to its support Mounting instructions 1 For stationary use place the saw in the desired location directly on a workbench where there is room for handling and proper support of the workpiece The base o...

Страница 15: ...e pieces removed noting their position and direction they face Wipe the blade collars clean of any sawdust before installing a new blade 10 Installing Blade Unplug the mitre saw before changing instal...

Страница 16: ...nto the lower table and check for any contact with the base or the mitre table by spinning the blade manually 11 Aligning the laser beam Warning For your own safety never connect the plug to power sou...

Страница 17: ...not ush with the pattern line adjust as follows in procedure B B Adjusting the Angle of the Laser Guide 1 Turn the laser element 3 in the desired direction to adjust the laser angle Note Do not adjus...

Страница 18: ...he mitre table with the ruler against the table and the heel of the square against the saw blade 3 If the blade is not 90o 0o square with the mitre table 5 loosen the bevel lock handle 1 tilt the cutt...

Страница 19: ...ndle 7 and locknut 8 when alignment is achieved See g 25 5 Mitre angle adjustment The sliding compound mitre saw scale can be easily read showing mitre angles from 0 to 45 to the left and 0 to 45 to t...

Страница 20: ...repetitive shallow cuts 1 Adjust the cutting head down See CUTTING HEAD section until the teeth of the blade are at the desired depth 2 While holding the upper arm in that position turn the stop knob...

Страница 21: ...ll overheat the motor If your mitre saw does not operate when plugged into an outlet have a professional electrician check the power supply Warning Avoid accidental starting Make sure the switch is in...

Страница 22: ...s a blade brake The brake is not a safety device Never rely on it to replace the proper use of the guard on your saw If the blade doesn t stop within approximately 8 seconds wait for the blade to stop...

Страница 23: ...handle 1 counterclockwise 2 While holding the mitre handle lift up on the positive stop locking lever 2 3 Rotate the mitre table to the right or left with the mitre handle 4 When the table is in the d...

Страница 24: ...e cutting head assembly should be drawn back completely then pushed forward when sawing Let the blade reach full speed before cutting This will help reduce the risk of a thrown workpiece To slide cut...

Страница 25: ...ive cutting Only use one stop plate at a time Loosen the locking bolt 2 rotate the stop plate 3 to vertical position and retighten the locking bolt See g 37 12 Auxiliary wood fence When making multipl...

Страница 26: ...he material See g 40 41 Note Always perform a dry run cut so you can determine if the operation being attempted is possible before power is applied to the saw Cutting crown molding Your compound mitre...

Страница 27: ...2 Mitre table set at RIGHT 31 6 3 LEFT side is nished piece Inside corner Right side IR 33 9 31 6 Left 1 Position bottom of molding against fence 2 Mitre table set at LEFT 31 6 3 LEFT side is nished p...

Страница 28: ...inal assembly to avoid electrical shock Replacing carbon brushes Replace both carbon brushes when either has less than 6 mm length of carbon remaining or if the spring or wire is damaged or burned To...

Страница 29: ...low out or vacuum up the sawdust Warning If blowing sawdust wear proper eye protection to keep debris from blowing into eyes Lubrication All the motor bearings in this tool are lubricated with a suf c...

Страница 30: ...upply voltage The power tool is supplied with a tted plug however if you should need to t a new plug follows the instruction below IMPORTANT The wire in the mains lead are coloured in accordance with...

Страница 31: ...ts of the following directives 89 336 EEC EMC Directive 2006 95 EC Low Voltage Directive 98 37 EC Machinery Directive Standards and technical speci cations referred to EN 55014 1 2000 A1 2001 A2 2002...

Страница 32: ...32 ERBAUER 216MM 8 SLIDING MITRE SAW...

Отзывы: