25
24
STANDARD SURFACE PLANING WITH OR WITHOUT THE PARALLEL
GUIDE (L, M)
Set the desired cutting depth. It is best to use small depths of cut and repeat the planing
process.
Attach the parallel guide (21) if required to the product as described above and adjust to
desired width.
Place the product laterally to the workpiece and guide the product along the edge.
NOTE:
Apply light lateral supporting pressure against the parallel guide
and keep the base plate flat on the surface to achieve an even result.
WARNING!
Danger of kickback! Apply the product to the workpiece only
when switched on!
REBATE PLANING (N)
Attach the parallel guide (21) and rebate depth gauge (19) to the product as described
above and adjust to desired width and depth.
Place the product laterally against the workpiece.
Guide the product along the edge, repeat until the desired depth has been reached.
NOTE:
Apply light lateral supporting pressure against the parallel guide
and keep the base plate flat on the surface to achieve an even result.
WARNING!
Danger of kickback! Apply the product to the workpiece only
when switched on!
OVERLOAD, TEMPERATURE AND CHARGING PROBLEM
Problem
Tool/ Battery Status
Possible cause
Solution
Overload
protection
Product suddenly
Stops; The LED
work light (if fitted) is
flashing
Extremely high
torque, binding and
stalling situations,
overloading of the
tool
Relieve the load immediately,
reset the tool by switching
off and back on again.
Temperature
extremely
high
The first and the
third LED light of the
POWER BAR will be
flashing alternately
Battery temperature
exceeds 77°C
during operation
Cool down the battery to
below 77°C for operation
and below 57°C for charging.
Low charge Power for the tool will
drop quickly; The first
LED on the POWER
BAR begins to flash
The battery pack is
under 5% charge
Remove the battery pack
from the tool and charge it
Other
problems
Short charges
Not fully charged
Make sure that the battery
is fully charged every time
by allowing the charger to
complete its full charging
cycle
Poor storage
condition
Always remove battery from
the tool and charger when
not in use and store in a dry
secure place. Avoid charging
or storing your battery in
temperatures below 5°C and
above 40°C. Cool down a
hot battery pack from a tool
that has just been operated
for approximately 30 minutes
before storage